BK5151, FC51xx, CX with CAN interface and EL6751: D-sub, 9 pin

The CANbus cable is connected to the FC51x1, FC51x2 CANopen cards and in the case of the EL6751 CANopen master/slave terminal via 9-pin Sub-D sockets with the following pin assignment.

Pin

Assignment

2

CAN low (CAN-)

3

CAN ground (internally connected to pin 6)

6

CAN ground (internally connected to pin 3)

7

CAN high (CAN+)

The unlisted pins are not connected.
The mounting rail contact spring and the plug shield are connected together.

Note: an auxiliary voltage of up to 30 VDC may be connected to pin 9. Some CAN devices use this to supply the transceiver.

BK5151, FC51xx, CX with CAN interface and EL6751: D-sub, 9 pin 1:Fig.17: BK5151, EL6751 pin assignment

FC51x2:

BK5151, FC51xx, CX with CAN interface and EL6751: D-sub, 9 pin 2:Fig.18: FC51x2