Objects for commissioning
Index 1018 Identity
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1018:0 |
Identity |
Information for identifying the slave |
UINT8 |
RO |
0x04 (4dec) |
|
1018:01 |
Vendor ID |
Vendor ID of the EtherCAT slave |
UINT32 |
RO |
0x00000002 (2dec) |
|
1018:02 |
Product code |
Product code of the EtherCAT slave |
UINT32 |
RO |
0x19C93052 (432615506dec) |
|
1018:03 |
Revision |
Revision number of the EtherCAT slave; the low word (bit 0-15) indicates the special terminal number, the high word (bit 16-31) refers to the device description |
UINT32 |
RO |
0x00100000 (1048576dec) |
|
1018:04 |
Serial number |
Serial number of the EtherCAT slave; the low byte (bit 0-7) of the low word contains the year of production, the high byte (bit 8-15) of the low word contains the week of production, the high word (bit 16-31) is 0 |
UINT32 |
RO |
0x00000000 (0dec) |
Index F800 EL6601 Para
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F800:0 | EL6601 Para | Max. subindex | UINT8 | RW | 0x02 (2dec) |
F800:01 | General | 0x0000: Standard operation 0x0001: VLAN TAGS are removed before filtering. 0x4000: EoE frames are blocked. | UINT16 | RW | 0x0000 (0dec) |
F800:02 | NetVars | This switch determines whether received subscriber data from frames with 0x88A4 in the header, that have not passed the subscriber filter, will be transported further via EoE/Mailbox to the EtherCAT Master. 0x0000: default, subscriber data are forwarded via EoE 0x0100: Subscriber data are being discarded | UINT16 | RW | 0x0000 (0dec) |