Introduction

Introduction 1:
Fig.1: EL6601, EL6614

EtherCAT Terminals, communication interface, Ethernet switch port

The switch terminals for Ethernet are used for decentralized connection of any Ethernet devices to the EtherCAT Terminal network. The Ethernet communication of the connected devices is forwarded by the EtherCAT system in a fully transparent and collision-free manner.

The EL6614 4-port Ethernet switch terminal forwards the incoming frames from the ports specifically to the target ports. In full duplex mode, it thus enables collision-free communication of the connected devices with each other.

Any number of EL6601/EL6614 devices can be used simultaneously and at any position in the EtherCAT Terminal network. No configuration is required. In conjunction with the network port at the EtherCAT master the EL6601/EL6614 devices operate like a virtual switch whose ports are distributed in the field. The EtherCAT fieldbus is the backbone of this switch.

Introduction 2:
Fig.2: EL6601 as a virtual, field-distributed switch

Further benefits underline the particular suitability for the application in industrial environments:

LED

LED

Color

Meaning

RUN

green

These LEDs indicate the terminal's operating state:

off

State of the EtherCAT State Machine: INIT = initialization of the terminal or BOOTSTRAP = function for terminal firmware updates

flashing

State of the EtherCAT State Machine: PREOP = function for mailbox communication and different default settings set

Single flash

State of the EtherCAT State Machine: SAFEOP = verification of the Sync Manager channels and the distributed clocks.
Outputs remain in safe state

on

State of the EtherCAT State Machine: OP = normal operating state; mailbox and process data communication is possible

Link / Act

green

Connection / data exchange fieldbus

*Link/Act  X1 - X4

green

Connection / data exchange Ethernet port  X1- X4

Eth Err

red

Error message EtherCAT (see Diagnostics)

* only EL6614

Connections

1 x RJ45 with 10BASE-T/100BASE-TX Ethernet (EL6601)
4 x RJ45 with 10BASE-T/100BASE-TX Ethernet (EL6614)