NC - Configuration
![]() | Installation of the latest XML device description Please ensure that you have installed the corresponding latest XML device description in TwinCAT. This can be downloaded from the Beckhoff Website and installed according to the installation instructions. |
The configuration of the axes and linking in the TwinCAT System Manager (Config mode) are described below, taking the EL5151 as an example. Proceed as follows:
- The terminal must already have been added manually under I/O devices or have been scanned in by the system (see section “Configuration set-up in TwinCAT”).
- Click with the right mouse button on NC Configuration -> Append task.
- Select a name for the task and confirm with OK.
- Click with the right mouse button on Axes - >Append axis.
- Select a name and type for the axis and confirm with OK.
- After selecting the NC-Encoder tab, select the encoder KL5101/Kl5111/IP5109/EL5101 in the pull-down menu Type.
- Click the Linked with... button, select the EL5151 terminal and confirm with OK.
- The respective inputs of the EL5151 are now linked with the NC task.
Fig.167: NC - Configuration, Append Task
Fig.168: Entering a name for the task and confirming
Fig.169: Insert axis
Fig.170: Entering a name for the axis and selecting a type
Fig.171: Selecting the encoder
Fig.172: Selecting and confirming an encoder terminal
Fig.173: EL5151 inputs linked with the NC task