EL5102 - Technical data
Technical data | EL5102 |
|---|---|
Encoder type | Incremental, differential (RS422), single-ended (TTL, open collector), counter, pulse generator |
Encoder connection | Differential inputs (RS422): A, A̅, B, B̅, C, C̅ Single-ended connection (TTL, Open Collector): A, B, C Counters, pulse generators: A, B |
Number of channels | 2 x A, B, C |
Additional inputs | Latch, Gate/Latch (24 VDC, tON > 1 µs) per channel, Status Input input (max. 5 VDC, negative switching, tON > 10 µs) per channel |
Encoder operating voltage | 5 VDC (preset), 12 VDC, 24 VDC switchable, 0.3 A per channel (generated from the 24 VDC power contacts) |
Counter | 32 bit (default) or 16 bit switchable |
Cut-off frequency | RS422 mode: 20 million increments/s with 4-fold evaluation, corresponds to 5 MHz TTL mode: 4 million increments/s with 4-fold evaluation, corresponds to 1 MHz Open Collector: 400,000 increments/s with 4-fold evaluation, corresponds to 100 kHz |
Quadrature decoder | 4-fold evaluation (preset), 2-fold, 1-fold evaluation switchable |
Micro-increments resolution | 1/256 bit micro-increments |
Broken wire detection to sensor | Yes for RS422 encoder |
Distributed Clocks | Yes |
Timestamp | Resolution 1 ns |
Special functions | Frequency, period duration and duty cycle measurement, micro increments, adjustable interference pulse filters, Timestamp on: last incremental edge, zero pulse C, Latch input and Gate/Latch input |
Cycle time | min. 100 µs |
Current consumption via E-bus | typ. 210 mA |
Current consumption from power contacts | typ. 20 mA + load |
Electrical isolation | 500 V (E-bus/field voltage) |
Configuration | via TwinCAT EtherCAT subscriber configuration |
Weight | approx. 100 g |
Permissible ambient temperature range during operation | 0°C ... +55°C |
Permissible ambient temperature range during storage | -25°C ... +85°C |
Permissible relative air humidity | 95%, no condensation |
Dimensions (W x H x D) | approx. 27 mm x 100 mm x 70 mm (width aligned: 24 mm) |
on 35 mm mounting rail according to EN 60715 | |
Enhanced mechanical load capacity | Yes, see also Installation instructions for enhanced mechanical load capacity |
Vibration / shock resistance | conforms to EN 60068-2-6 / EN 60068-2-27 |
EMC immunity / emission | conforms to EN 61000-6-2 / EN 61000-6-4 |
Protection class | IP20 |
Installation position | variable |
Approvals / markings* | CE, EAC, UKCA, cULus |
*) Real applicable approvals/markings see type plate on the side (product marking).