Supported encoders / signal types
Differential signals according to RS422 are intended as encoder connection. Single-ended signals from TTL encoders and also signals from Open Collector encoders are also options, through internal pull-up resistances.
The following signal types are supported:
Encoder | Signal type | Setting in | Cut-off frequency | Comments |
|---|---|---|---|---|
Encoder | RS422 | 0 | 20 million increments/s | Signal levels according to RS422 are expected |
Counter/pulse generator | 1 | |||
Encoder | TTL | 2 | 4 million increments/s | A voltage level of nominally 2.0 V to 6.0 V with a current of 2.1 mA or higher is expected. No wire break detection |
Counter/pulse generator | 3 | |||
Encoder | open collector | 4 | 400,000 increments/s | No wire break detection |
Counter/pulse generator | 5 | |||
*) depending on the number of channels (n = 0 for channel 1 and n = 1 for channel 2) | ||||
The correct wiring for the respective encoder can be found in chapter Connection.