Peter Hirt GmbH sensors

Series:
Probes T101 / T102

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T101F

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T102F

T101V

T102V

T101P

T102P

T101L

T102L

Series:
Probes T151 / T152

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T151F

Full Bridge (LVDT)

5dec: “5-wire LVDT”

0dec: “High impedance / Marposs®”

T152F

T151V

T152V

T151P

T152P

T151L

T152L

Series:
Probes T151 / T152

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T151F-024

Marposs

5dec: “5-wire LVDT”

0dec: “High impedance / Marposs®”

T152F-024

T151V-024

T152V-024

T151P-024

T152P-024

T151L-024

T152L-024

Series:
Probes T161 / T162

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T161F

Mahr

4dec: “4-wire LVDT”

1dec: “Mahr® impedance”

T162F

T161V

T162V

T161P

T162P

T161L

T162L

Series:
Probes T201 / T202

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T201F

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T202F

T202V

T202P

T202L

Series:
Probes T301 / T302

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T301F

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T302F

T301V

T302V

T301P

T302P

T301L

T302L

Series:
Probes T401 / T402, T451 / T452

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T401

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T402

T451

Full Bridge (LVDT)

5dec: “5-wire LVDT”

0dec: “High impedance / Marposs®”

T452

Series:
Probes T501 / T502

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T501F

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T502F

T501V

T502V

T501P

T502P

T501L

T502L

Series:
Probes T521 / T522

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T521F

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T522F

T521V

T522V

T521P

T522P

T521L

T522L

Series:
Probes T523 / T524

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T523F

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T524F

T523V

T524V

T523P

T524P

T523L

T524L

Series:
Probes T801 / T802

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T801

Half Bridge

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

T802

Series:
Probes T851 / T852

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

T851

Full Bridge (LVDT)

5dec: “5-wire LVDT”

0dec: “High impedance / Marposs®”

T852

Series:
Probes 10P0 / 10P1 / 1P0

EL5072
Setting recommendations

Manufacturer designation

Compatibility

0x80n1:12
„Connection type“

0x80n1:13
„Sensor impedance“

10P0

Tesa

13dec: “3-wire Half Bridge”

2dec: “Tesa® impedance”

10P1

1P00