Diagnostic data

Index 10F3 Diagnosis History

Index (hex)

Name

Meaning

Data type

Flags

Default

10F3:0

Diagnosis History

Maximum subindex

UINT8

RO

0x37 (55dec)

10F3:01

Maximum Messages

Maximum number of stored messages
A maximum of 50 messages can be stored

UINT8

RO

0x32 (50dec)

10F3:02

Newest Message

Subindex of the latest message

UINT8

RO

0x00 (0dec)

10F3:03

Newest Acknowledged Message

Subindex of the last confirmed message

UINT8

RW

0x00 (0dec)

10F3:04

New Messages Available

Indicates that a new message is available

BOOLEAN

RO

FALSE

10F3:05

Flags

not used

UINT16

RW

0x0000 (0dec)

10F3:06

Diagnosis Message 001

Message 1

OCTET-STRING[28]

RO

 

...

...

...

 

 

 

10F3:37

Diagnosis Message 050

Message 50

OCTET-STRING[28]

RO

 

Index 10F8 Actual Time Stamp

Index (hex)

Name

Meaning

Data type

Flags

Default

10F8:0

Actual Time Stamp

Time stamp

UINT64

RO

 

Index A0p8 FB BiSS-C Diag data (for Ch.1, p = 0; Ch.2, p = 1)

Index (hex)

Name

Meaning

Data type

Flags

Default

A0p8:0

FB BiSS-C Diag data

Max. Subindex

UINT8

RO

0x11 (17dec)

A0p8:01

Power Supply Present

Power Supply present

BOOLEAN

RO

FALSE

A0p8:02

Error

Error occured

BOOLEAN

RO

FALSE

A0p8:03

SCD Error

Sync Data Error occurred

BOOLEAN

RO

FALSE

A0p8:04

WD Error

Watch Dog Error occurred

BOOLEAN

RO

FALSE

A0p8:05

Data valid

Valid data present

BOOLEAN

RO

FALSE

A0p8:11

Data raw value

Position value without invertion and offset

UINT64

RO

00 00 00 00 00 00 00 00