Diagnostic data
Index 10F3 Diagnosis History
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   10F3:0  | 
                   Diagnosis History  | 
                   Maximum subindex  | 
                   UINT8  | 
                   RO  | 
                   > 55 <  | 
| 
                   10F3:01  | 
                   Maximum Messages  | 
                   Maximum number of stored messages  | 
                   UINT8  | 
                   RO  | 
                   0x32 (50dec)  | 
| 
                   10F3:02  | 
                   Newest Message  | 
                   Subindex of the latest message  | 
                   UINT8  | 
                   RO  | 
                   0x00 (0dec)  | 
| 
                   10F3:03  | 
                   Newest Acknowledged Message  | 
                   Subindex of the last confirmed message  | 
                   UINT8  | 
                   RW  | 
                   0x00 (0dec)  | 
| 
                   10F3:04  | 
                   New Messages Available  | 
                   Indicates that a new message is available  | 
                   BOOLEAN  | 
                   RO  | 
                   FALSE  | 
| 
                   10F3:05  | 
                   Flags  | 
                   not used  | 
                   UINT16  | 
                   RW  | 
                   0x0000 (0dec)  | 
| 
                   10F3:06  | 
                   Diagnosis Message 001  | 
                   Message 1  | 
                   OCTET-STRING[28]  | 
                   RO  | 
                   
  | 
| 
                   ...  | 
                   ...  | 
                   ...  | 
                   
  | 
                   
  | 
                   
  | 
| 
                   10F3:37  | 
                   Diagnosis Message 050  | 
                   Message 50  | 
                   OCTET-STRING[28]  | 
                   RO  | 
                   
  | 
Index 10F8 Actual Time Stamp
| 
                   Index (hex)  | 
                   Name  | 
                   Meaning  | 
                   Data type  | 
                   Flags  | 
                   Default  | 
|---|---|---|---|---|---|
| 
                   10F8:0  | 
                   Actual Time Stamp  | 
                   Time stamp  | 
                   UINT64  | 
                   RO  | 
                   
  | 
Index A0p8 FB EnDat Diag data (dependent on the number of channels for Ch.1, p = 0; Ch.2, p = 1)
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
A0p8:0  | FB EnDat Diag data  | Max. subindex  | UINT8  | RO  | > 67 <  | 
A0p8:01  | Warning  | Warning bit of the EnDat protocol 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:02  | Error 1  | Error 2 bit of the EnDat protocol 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:03  | Error 2 (active low)  | Error 2 bit of the EnDat protocol 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:04  | Reference Mark  | 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:11  | CRC Error Position counter  | Incremented with each "CRC Error Position"  | UINT16  | RW  | 0x0000 (0dec)  | 
A0p8:12  | CRC Error Z1 counter  | Incremented with each "CRC error additional information 1"  | UINT16  | RW  | 0x0000 (0dec)  | 
A0p8:13  | CRC Error Z2 counter  | Incremented with each "CRC error additional information 2"  | UINT16  | RW  | 0x0000 (0dec)  | 
A0p8:21  | Light source error  | Lighting 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:22  | Signal amplitude error  | Signal amplitude 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:23  | Position error  | Position 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:24  | Overvoltage error  | Overvoltage 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:25  | Undervoltage error  | Undervoltage 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:26  | Overcurrent error  | Overcurrent 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:27  | Battery error  | Battery 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:31  | Frequency warning  | Frequency collision 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:32  | Temperature warning  | Overtemperature 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:33  | Light source warning  | Lighting control reserve 
  | BOOLEAN  | RO  | FALSE  | 
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
A0p8:34  | Battery warning  | Battery charge level 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:35  | Reference mark warning  | Reference point 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:36  | Acyclic mode warning  | Cyclic operation 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:37  | Limit position warning  | Limit position 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:38  | Not ready warning  | Readiness 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:39  | Diagnostic warning  | Diagnosis 
  | BOOLEAN  | RO  | FALSE  | 
A0p8:41  | Temperature sensor 1 (extern)  | Temperature sensor 1 (0x8000 is output if not supported)  | INT16  | RO  | 0x8000  | 
A0p8:42  | Temperature sensor 2 (extern)  | Temperature sensor 1 (0x8000 is output if not supported)  | INT16  | RO  | 0x8000  | 
A0p8:43  | Position raw value  | Position value without inversion and offset  | UINT64  | RO  | 00 00 00 00 00 00 00 00  |