Information data
(Electronic type plate and list of the supported errors and warnings)
Index 90p8 FB EnDat Info data (dependent on the number of channels for Ch.1, p = 0; Ch.2, p = 1)
Index (hex)  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
90p8:0  | FB ENDat Info data  | Max. subindex  | UINT8  | RO  | > 81 <  | 
90p8:01  | Encoder type  | 0: "Linear encoder"  | BIT2  | RO  | Linear encoder (0dec)  | 
90p8:03  | Reference system  | 0: "Incremental"  | BIT1  | RO  | Incremental (0dec)  | 
90p8:11  | Encoder designation  | Encoder designation, e.g.: LC181  | STRING  | RO  | 
  | 
90p8:12  | Encoder ident number  | Encoder ident number  | STRING  | RO  | 
  | 
90p8:13  | Encoder serial number  | Encoder serial number  | STRING  | RO  | 
  | 
90p8:14  | Multiturn resolution  | Number of distinguishable revolutions e.g: 4096 (corresponds to 12 bit)  | UINT32  | RO  | 0x00000000 (0dec)  | 
90p8:15  | Singleturn resolution  | “Rotary/angle encoder” only: number of measuring steps per revolution  | UINT32  | RO  | 0x00000000 (0dec)  | 
90p8:16  | Measuring step  | “Linear encoder” only: step size in nm  | UINT32  | RO  | 0x00000000 (0dec)  | 
90p8:21  | Light source error supported  | Corresponding diagnostic entry in 0xA0p8  | BOOLEAN  | RO  | FALSE  | 
90p8:22  | Signal amplitude error supported  | ||||
90p8:23  | Position error supported  | ||||
90p8:24  | Overvoltage error supported  | ||||
90p8:25  | Undervoltage error supported  | ||||
90p8:26  | Overcurrent error supported  | ||||
90p8:27  | Battery error supported  | ||||
90p8:31  | Frequency warning supported  | ||||
90p8:32  | Temperature warning supported  | ||||
90p8:33  | Light source warning supported  | ||||
90p8:34  | Battery warning supported  | ||||
90p8:35  | Reference Mark warning supported  | ||||
90p8:36  | Acyclic mode warning supported  | ||||
90p8:37  | Limit position warning supported  | ||||
90p8:38  | Not ready warning supported  | ||||
90p8:39  | Diagnostic warning supported  | ||||
90p8:43  | Temperature 1 (extern) supported  | ||||
90p8:44  | Temperature 2 (intern) supported  | ||||
90p8:51  | Clock pulse periods  | Number of position bits  | UINT16  | RO  | 0x0000 (0dec)  | 