Technical data

Technical data 1:

RMS value (rms) specifications

All AC value specifications in this documentation such as RMS specifications (rms) refer to a 50/60 Hz 3-phase mains network with a sinusoidal waveform (crest factor 1.414).

Technical data

EL3773

Number of inputs

3 x current, 3 x voltage

Oversampling factor

n = 1…100 selectable

Distributed Clocks

yes

Accuracy of Distributed Clocks

<< 1 µs

Input filter limit frequency

adjustable, 200 ... 15,000 Hz

Conversion time

min. 100 µs, all channels measured simultaneously

Sampling type

simultaneous

Ground reference

single ended

Rated mains voltage

230 Vrms (ULX-N) or 400 Vrms (ULX-ULY)

Voltage measuring range (nominal range)

DC: ±410 V

AC accordingly: 500 Vrms AC 3~ (ULX-N: 288 Vrms AC)
common reference potential N/GND **)

Max. permitted overvoltage

max. ±500 V (peak value, ULX-N, corresponds with 353 Vrms) **)

Voltage resolution

1 digit ~ 12.5 mV (16 bit incl. sign)

Input resistance voltage circuit

typ. 1.8 MΩ

Current measuring range (nominal range)

DC: ±1.5 A

AC accordingly: 3 x 1 Arms **)

AC recommended via measuring transformer x A AC/1 A AC

Max. permitted overcurrent

max. ±1.8 A (peak value, corresponds with 1.2 Arms) **)

the upstream use of current/limiting current transformers is recommended

Current resolution

1 digit ~ 45.7 µA (16 bit incl. sign)

Input resistance current path

typ. 30 mΩ

Signal type

variable

Measuring error (for DC measuring)

< ±0.5 % (relative to full scale value)

Electrical isolation

2,500 V

Current consumption of power contacts

-

Current consumption via E-bus

200 mA typ.

Configuration

via TwinCAT System Manager

Weight

approx. 75 g

permissible ambient temperature range during operation

0°C ... +55°C

permissible ambient temperature range during storage

-25°C ... +85°C

permissible relative humidity

95 %, no condensation

Dimensions (W x H x D)

approx. 15 mm x 100 mm x 70 mm

Mounting

on 35 mm mounting rail conforms to EN 60715

Vibration/shock resistance

conforms to EN 60068-2-6 / EN 60068-2-27,
see also installation instructions for enhanced mechanical load capacity

EMC immunity/emission

conforms to EN 61000-6-2 / EN 61000-6-4

Protection class

IP20

Installation position

variable

Marking / Approval *)

CE,
cULus

*) Real applicable approvals/markings see type plate on the side (product marking).

**) Operation for longer periods above the rated range can impair the function and/or lead to a shortening of the service life