Standard objects (0x1000-0x1FFF)
The standard objects have the same meaning for all EtherCAT slaves.
Index 1000 Device type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1000:0 |
Device type |
Device type of the EtherCAT slave: the Lo-Word contains the CoE profile used (5001). The Hi-Word contains the module profile according to the modular device profile. |
UINT32 |
RO |
0x014A1389 (21631881dec) |
Index 1008 Device name
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1008:0 |
Device name |
Device name of the EtherCAT slave |
STRING |
RO |
EL3314-0000 |
Index 1009 Hardware version
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1009:0 |
Hardware version |
Hardware version of the EtherCAT slave |
STRING |
RO |
00 |
Index 100A Software version
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
100A:0 |
Software version |
Firmware version of the EtherCAT slave |
STRING |
RO |
01 |
Index 1018 Identity
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1018:0 |
Identity |
Information for identifying the slave |
UINT8 |
RO |
0x04 (4dec) |
|
1018:01 |
Vendor ID |
Vendor ID of the EtherCAT slave |
UINT32 |
RO |
0x00000002 (2dec) |
|
1018:02 |
Product code |
Product code of the EtherCAT slave |
UINT32 |
RO |
0x0CF23052 (217198674dec) |
|
1018:03 |
Revision |
Revision number of the EtherCAT slave; the low word (bit 0-15) indicates the special terminal number, the high word (bit 16-31) refers to the device description |
UINT32 |
RO |
0x00100000 (1048576dec) |
|
1018:04 |
Serial number |
empty |
UINT32 |
RO |
0x00000000 (0dec) |
Index 10F0 Backup parameter handling
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
10F0:0 |
Backup parameter handling |
Information for standardized loading and saving of backup entries |
UINT8 |
RO |
0x01 (1dec) |
|
10F0:01 |
Checksum |
Checksum across all backup entries of the EtherCAT slave |
UINT32 |
RO |
0x00000000 (0dec) |
Index 160n RxPDO-Map Range (Ch1 n=0; Ch2 n=1)
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
160n:0 |
RxPDO-Map Ch.1 |
PDO Mapping RxPDO n |
UINT8 |
RO |
0x05 (5dec) |
|
160n:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7000 (SAI Range), entry 0x01 (Disable Autorange)) |
UINT32 |
RO |
0x7000:01, 1 |
|
160n:02 |
SubIndex 002 |
2. PDO Mapping entry (Fill Bits) |
UINT32 |
RO |
0x0000:00, 2 |
|
160n:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7000 (SAI Range), entry 0x04 (Start conversion)) |
UINT32 |
RO |
0x7000:04, 1 |
|
160n:04 |
SubIndex 004 |
4. PDO Mapping entry (object 0x7000 (SAI Range), entry 0x05 (Mode)) |
UINT32 |
RO |
0x7000:05, 4 |
|
160n:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x7000 (SAI Range), entry 0x09 (Range)) |
UINT32 |
RO |
0x7000:09, 8 |
Index 1A0n TxPDO-Map Inputs (Ch1 n=0; Ch2 n=3)
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0n:0 |
TxPDO-ParCh.1 |
PDO Parameter TxPDO 1 |
UINT8 |
RO |
0x0C (12dec) |
|
1A0n:01 |
SubIndex 001 |
1. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x01 (Underrange)) |
UINT32 |
RO |
0x6000:01, 1 |
|
1A0n:02 |
SubIndex 002 |
2. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x02 (Overrange)) |
UINT32 |
RO |
0x6000:02, 1 |
|
1A0n:03 |
SubIndex 003 |
3. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x03 (Extended Range)) |
UINT32 |
RO |
0x6000:03, 1 |
|
1A0n:04 |
SubIndex 004 |
4. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x04 (Data Invalid)) |
UINT32 |
RO |
0x6000:04, 1 |
|
1A0n:05 |
SubIndex 005 |
5. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x05 (Range Invalid)) |
UINT32 |
RO |
0x6000:05, 1 |
|
1A0n:06 |
SubIndex 006 |
6. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x06 (Autorange disabled)) |
UINT32 |
RO |
0x6000:06, 1 |
|
1A0n:07 |
SubIndex 007 |
7. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x07 (Error)) |
UINT32 |
RO |
0x6000:07, 1 |
|
1A0n:08 |
SubIndex 008 |
8. PDO Mapping entry (Fill Bits) |
UINT32 |
RO |
0x0000:00, 1 |
|
1A0n:09 |
SubIndex 009 |
9. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x09 (Steady state)) |
UINT32 |
RO |
0x6000:07, 1 |
|
1A0n:0A |
SubIndex 010 |
10. PDO Mapping entry (Fill Bits) |
UINT32 |
RO |
0x0000:00, 5 |
|
1A0n:0B |
SubIndex 011 |
11. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x0F (TxPDO State)) |
UINT32 |
RO |
0x6000:0F, 1 |
|
1A0n:0C |
SubIndex 012 |
12. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x10 (TxPDO Toogle)) |
UINT32 |
RO |
0x6000:10, 1 |
|
1A0n:0D |
SubIndex 013 |
13. PDO Mapping Entry (object 0x6000 (SAI Inputs), entry 0x11 (INT Value)) |
UINT32 |
RO |
0x6000:11, 32 |
Index 1A0n TxPDO-Map Inputs Real (Ch1 n=2; Ch2 n=5)
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0n:0 |
TxPDO-ParCh.1 |
PDO Parameter TxPDO 1 |
UINT8 |
RO |
0x01 (1dec) |
|
1A0n:01 |
SubIndex 001 |
1. PDO Mapping Entry (object 0x6002 (SAI Inputs Real), entry 0x01 (Range)) |
UINT32 |
RO |
0x6002:01, 32 |
Index 1A0n TxPDO-Map Range (Ch1 n=1; Ch2 n=4)
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0n:0 |
TxPDO-ParCh.1 |
PDO Parameter TxPDO 1 |
UINT8 |
RO |
0x03 (3dec) |
|
1A0n:01 |
SubIndex 001 |
1. PDO Mapping Entry (Fill Bits) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0n:02 |
SubIndex 002 |
2. PDO Mapping Entry (object 0x6001 (SAI Range), entry 0x05 (Mode)) |
UINT32 |
RO |
0x6001:05, 4 |
|
1A0n:03 |
SubIndex 003 |
3. PDO Mapping Entry (object 0x6001 (SAI Range), entry 0x09 (Range)) |
UINT32 |
RO |
0x6001:09, 8 |
Index 1C00 Sync manager type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C00:0 |
Sync manager type |
Using the sync managers |
UINT8 |
RO |
0x04 (4dec) |
|
1C00:01 |
SubIndex 001 |
Sync-Manager Type Channel 1: Mailbox Write |
UINT8 |
RO |
0x01 (1dec) |
|
1C00:02 |
SubIndex 002 |
Sync-Manager Type Channel 2: Mailbox Read |
UINT8 |
RO |
0x02 (2dec) |
|
1C00:03 |
SubIndex 003 |
Sync-Manager Type Channel 3: Process Data Write (Outputs) |
UINT8 |
RO |
0x03 (3dec) |
|
1C00:04 |
SubIndex 004 |
Sync-Manager Type Channel 4: Process Data Read (Inputs) |
UINT8 |
RO |
0x04 (4dec) |
Index 1C12 RxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C12:0 |
RxPDO assign |
PDO Assign Outputs |
UINT8 |
RW |
0x02 (2dec) |
|
1C12:01 |
Subindex 001 |
1. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1600 (5632dec) |
|
1C12:02 |
Subindex 002 |
2. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1601 (5633dec) |
Index 1C13 TxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C13:0 |
TxPDO assign |
PDO Assign Inputs |
UINT8 |
RW |
0x06 (6dec) |
|
1C13:01 |
Subindex 001 |
1. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A00 (6656dec) |
|
1C13:02 |
Subindex 002 |
2. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A01 (6657dec) |
|
1C13:03 |
Subindex 003 |
3. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A02 (6658dec) |
|
1C13:04 |
Subindex 004 |
4. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A03 (6659dec) |
|
1C13:05 |
Subindex 005 |
5. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A04 (6660dec) |
|
1C13:06 |
Subindex 006 |
6. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A05 (6661dec) |
Index 1C32 SM output parameter
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C32:0 |
SM output parameter |
Synchronization parameters for the outputs |
UINT8 |
RO |
0x07 (7dec) |
|
1C32:01 |
Sync mode |
Current synchronization mode:
|
UINT16 |
RW |
0x0000 (0dec) |
|
1C32:02 |
Cycle time |
Cycle time (in ns):
|
UINT32 |
RW |
0x00000000 (0dec) |
|
1C32:03 |
Shift time |
Time between SYNC0 event and output of the outputs (in ns, DC mode only) |
UINT32 |
RW |
0x00000000 (0dec) |
|
1C32:04 |
Sync modes supported |
Supported synchronization modes:
|
UINT16 |
RO |
0x8007 (32775dec) |
|
1C32:05 |
Minimum cycle time |
Minimum cycle time (in ns) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C32:06 |
Calc and copy time |
Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C32:08 |
Command |
The entries 0x1C32:03, 0x1C32:05, 0x1C32:06, 0x1C32:09, 0x1C33:03, 0x1C33:06, 0x1C33:09 are updated with the maximum measured values. |
UINT16 |
RW |
0x0000 (0dec) |
|
1C32:09 |
Delay time |
Time between SYNC1 event and output of the outputs (in ns, DC mode only) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C32:0B |
SM event missed counter |
Number of missed SM events in OPERATIONAL (DC mode only) |
UINT16 |
RO |
0x0000 (0dec) |
|
1C32:0C |
Cycle exceeded counter |
Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early) |
UINT16 |
RO |
0x0000 (0dec) |
|
1C32:0D |
Shift too short counter |
Number of occasions that the interval between SYNC0 and SYNC1 event was too short (DC mode only) |
UINT16 |
RO |
0x0000 (0dec) |
|
1C32:20 |
Sync error |
The synchronization was not correct in the last cycle (outputs were output too late; DC mode only) |
BOOLEAN |
RO |
0x00 (0dec) |
Index 1C33 SM input parameter
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C33:0 |
SM input parameter |
Synchronization parameters for the inputs |
UINT8 |
RO |
0x07 (7dec) |
|
1C33:01 |
Sync mode |
Current synchronization mode:
|
UINT16 |
RW |
0x0000 (0dec) |
|
1C33:02 |
Cycle time |
as 0x1C32:02 |
UINT32 |
RW |
0x00000000 (0dec) |
|
1C33:03 |
Shift time |
Time between SYNC0 event and reading of the inputs (in ns, only DC mode) |
UINT32 |
RW |
0x00000000 (0dec) |
|
1C33:04 |
Sync modes supported |
Supported synchronization modes:
|
UINT16 |
RO |
0x8007 (32775dec) |
|
1C33:05 |
Minimum cycle time |
as 0x1C32:05 |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C33:06 |
Calc and copy time |
Time between reading of the inputs and availability of the inputs for the master (in ns, only DC mode) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C33:08 |
Command |
as 0x1C32:08 |
UINT16 |
RW |
0x0000 (0dec) |
|
1C33:09 |
Delay time |
Time between SYNC1 event and reading of the inputs (in ns, only DC mode) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C33:0B |
SM event missed counter |
as 0x1C32:11 |
UINT16 |
RO |
0x0000 (0dec) |
|
1C33:0C |
Cycle exceeded counter |
as 0x1C32:12 |
UINT16 |
RO |
0x0000 (0dec) |
|
1C33:0D |
Shift too short counter |
as 1C32:13 |
UINT16 |
RO |
0x0000 (0dec) |
|
1C33:20 |
Sync error |
as 0x1C32:32 |
BOOLEAN |
RO |
0x00 (0dec) |