Standard objects
Standard objects (0x1000-0x1FFF)
The standard objects have the same meaning for all EtherCAT slaves.
Index 1000 Device type
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1000:0 | Device type | Device type of the EtherCAT slave: The Lo-Word contains the CoE profile used (5001). The Hi-Word contains the module profile according to the modular device profile. | UINT32 | RO | 0x01551389 (22352777dec) |
Index 1008 Device name
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1008:0 | Device name | Device name of the EtherCAT slave | STRING | RO | EL34xx |
Index 1009 Hardware version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1009:0 | Hardware version | Hardware version of the EtherCAT slave | STRING | RO |
|
Index 100A Software Version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100A:0 | Software version | Firmware version of the EtherCAT slave | STRING | RO |
|
Index 100B Bootloader version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100B:0 | Bootloader version | Bootloader version | STRING | RO |
|
Index 1018 Identity
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1018:0 | Identity | Length of this object | UINT8 | RO | 0x04 (4dec) |
1018:01 | Vendor ID | Vendor ID of the EtherCAT slave | UINT32 | RO | 0x00000002 (2dec) |
1018:02 | Product code | Product code of the EtherCAT slave | UINT32 | RO | 0x0D5F3052 (224342098dec) |
1018:03 | Revision | Revision number of the EtherCAT slave; the Low Word (bit 0-15) indicates the special terminal number, the High Word (bit 16-31) refers to the device description | UINT32 | RO | -- |
1018:04 | Serial number | Serial number of the EtherCAT slave; the Low Byte (bit 0-7) of the Low Word contains the year of production, the High Byte (bit 8-15) of the Low Word contains the week of production, the High Word (bit 16-31) is 0 | UINT32 | RO | e.g. 0x00001E06 (week 30/2006) |
Index 10F0 Backup parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F0:0 | Backup parameter | Length of this object | UINT8 | RO | 0x01 |
10F0:01 | Checksum | Checksum | UINT32 | RW | 0x00000000 (0dec) |
Index 10F3 Diagnosis History
Index | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F3:0 | Diagnosis History | Maximum subindex | UINT8 | RO | 0x15 (21dec) |
10F3:01 | Maximum Messages | Maximum number of stored messages. A maximum of 50 messages can be stored | UINT8 | RO | 0x00 (0dec) |
10F3:02 | Newest Message | Subindex of the latest message | UINT8 | RO | 0x00 (0dec) |
10F3:03 | Newest Acknowledged Message | Subindex of the last confirmed message | UINT8 | RW | 0x00 (0dec) |
10F3:04 | New Messages Available | Indicates that a new message is available | BOOLEAN | RO | 0x00 (0dec) |
10F3:05 | Flags | not used | UINT16 | RW | 0x0000 (0dec) |
10F3:06 | Diagnosis Message 001 | Message 1 | OCTET STRING[28] | RO | {0} |
... | ... | ... | ... | ... | ... |
10F3:15 | Diagnosis Message 016 | Message 16 | OCTET STRING[28] | RO | {0} |
Index 10F8 Actual Time Stamp
Index | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F8:0 | Actual Time Stamp | Time stamp | UINT64 | RO | 0x0000000000000000 (0dec) |
Index 10F9 Time Distribution Object
Index | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F9:0 | Time Distribution Object | Max Subindex | UINT8 | RO | 0x01 (1dec) |
10F9:01 | Distributed Time Value | Object for time distribution by the EtherCAT Master | INT64 | RW |
|
Index 1601 Total RxPDO-Map Interval
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1601:0 | Total RxPDO-Map Interval | PDO Mapping RxPDO | UINT8 | RO | 0x02 (2dec) |
1601:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF701 (PMX Interval), entry 0x01 (Reset Interval)) | UINT32 | RO | 0xF701:01, 1 |
1601:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
Index 1App TxPDO-Map Status (for L1, pp = 00; L2, pp = 0A; L3, pp = 14)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1App:0 | TxPDO-Map Status | PDO Mapping TxPDO | UINT8 | RO | 0x09 (9dec) |
1App:01 | SubIndex 001 | 1. PDO Mapping entry (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1App:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x02 (Overvoltage)) | UINT32 | RO | 0x60n0:02, 1** |
1App:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x03 (Overcurrent)) | UINT32 | RO | 0x60n0:03, 1** |
1App:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x04 (Inaccurate Voltage)) | UINT32 | RO | 0x60n0:04, 1** |
1App:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x05 (Inaccurate Current)) | UINT32 | RO | 0x60n0:05, 1** |
1App:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x06 (Voltage Guard Warning)) | UINT32 | RO | 0x60n0:06, 1** |
1App:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x07 (Voltage Guard Error)) | UINT32 | RO | 0x60n0:07, 1** |
1App:08 | SubIndex 008 | 8. PDO Mapping entry (8 bits align) | UINT32 | RO | 0x0000:00, 8** |
1App:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x60n0 (PMX Status), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0x60n0:10, 1** |
**) for L1, n = 0; L2, n = 1; L3, n = 2) | |||||
Index 1App TxPDO-Map Energy (for L1, pp = 03; L2, pp = 0D; L3, pp = 17)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1App:0 | TxPDO-Map Energy | PDO Mapping TxPDO | UINT8 | RO | 0x03 (3dec) |
1App:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x60n4 (PMX Energy), entry 0x11 (Active Energy)) | UINT32 | RO | 0x60n4:11, 64** |
1App:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x60n4 (PMX Energy), entry 0x12 (Apparent Energy)) | UINT32 | RO | 0x60n4:12, 64** |
1App:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x60n4 (PMX Energy), entry 0x13 (Reactive Energy)) | UINT32 | RO | 0x60n4:13, 64** |
**) for L1, n = 0; L2, n = 1; L3, n = 2) | |||||
Index 1App TxPDO-Map Statistic Voltage (for L1, pp = 06; L2, pp = 10; L3, pp = 1A)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1App:0 | TxPDO-Map Statistic Voltage | PDO Mapping TxPDO | UINT8 | RO | 0x03 (3dec) |
1App:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x60n8 (PMX Statistic Voltage), entry 0x11 (Voltage Peak)) | UINT32 | RO | 0x60n8:11, 32** |
1App:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x60n8 (PMX Statistic Voltage), entry 0x12 (Voltage RMS Minimum)) | UINT32 | RO | 0x60n8:12, 32** |
1App:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x60n8 (PMX Statistic Voltage), entry 0x13 (Voltage RMS Maximum)) | UINT32 | RO | 0x60n8:13, 32** |
**) for L1, n = 0; L2, n = 1; L3, n = 2) | |||||
Index 1App TxPDO-Map Statistic Current (for L1, pp = 07; L2, pp = 11; L3, pp = 1B)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1App:0 | L1 TxPDO-Map Statistic Current | PDO Mapping TxPDO | UINT8 | RO | 0x03 (3dec) |
1App:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x60n9 (PMX Statistic Current), entry 0x11 (Current Peak)) | UINT32 | RO | 0x60n9:11, 32** |
1App:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x60n9 (PMX Statistic Current), entry 0x12 (Current RMS Minimum)) | UINT32 | RO | 0x60n9:12, 32** |
1App:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x60n9 (PMX Statistic Current), entry 0x13 (Current RMS Maximum)) | UINT32 | RO | 0x60n9:13, 32** |
**) for L1, n = 0; L2, n = 1; L3, n = 2) | |||||
Index 1App TxPDO-Map Statistic Power (for L1, pp = 08; L2, pp = 12; L3, pp = 1C)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1App:0 | TxPDO-Map Statistic Power | PDO Mapping TxPDO | UINT8 | RO | 0x09 (9dec) |
1App:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x11 (Active Power Avg)) | UINT32 | RO | 0x60nA:11, 32** |
1App:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x12 (Active Power Min)) | UINT32 | RO | 0x60nA:12, 32** |
1App:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x13 (Active Power Max)) | UINT32 | RO | 0x60nA:13, 32** |
1App:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x14 (Apparent Power Avg)) | UINT32 | RO | 0x60nA:14, 32** |
1App:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x15 (Apparent Power Max)) | UINT32 | RO | 0x60nA:15, 32** |
1App:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x16 (Reactive Power Avg)) | UINT32 | RO | 0x60nA:16, 32** |
1App:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x17 (Reactive Power Min)) | UINT32 | RO | 0x60nA:17, 32** |
1App:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x18 (Reactive Power Max)) | UINT32 | RO | 0x60nA:18, 32** |
1App:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x60nA (PMX Statistic Power), entry 0x19 (Apparent Power Min)) | UINT32 | RO | 0x60nA:19, 32** |
**) for L1, n = 0; L2, n = 1; L3, n = 2) | |||||
Index 1A1E Total TxPDO-Map Total Status
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A1E:0 | Total TxPDO-Map Total Status | PDO Mapping TxPDO | UINT8 | RO | 0x10 (16dec) |
1A1E:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x01 (System State)) | UINT32 | RO | 0xF600:01, 1 |
1A1E:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x02 (Grid Direction)) | UINT32 | RO | 0xF600:02, 1 |
1A1E:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x03 (Frequency Guard Warning)) | UINT32 | RO | 0xF600:03, 1 |
1A1E:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x04 (Frequency Guard Error)) | UINT32 | RO | 0xF600:04, 1 |
1A1E:05 | SubIndex 005 | 5. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x05 (Neutral Current Guard Warning)) | UINT32 | RO | 0xF600:05, 1 |
1A1E:06 | SubIndex 006 | 6. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x06 (Neutral Current Guard Error)) | UINT32 | RO | 0xF600:06, 1 |
1A1E:07 | SubIndex 007 | 7. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x07 (Active Power Guard Warning)) | UINT32 | RO | 0xF600:07, 1 |
1A1E:08 | SubIndex 008 | 8. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x08 (Active Power Guard Error)) | UINT32 | RO | 0xF600:08, 1 |
1A1E:09 | SubIndex 009 | 9. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x09 (Apparent Power Guard Warning)) | UINT32 | RO | 0xF600:09, 1 |
1A1E:0A | SubIndex 010 | 10. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x0A (Apparent Power Guard Error)) | UINT32 | RO | 0xF600:0A, 1 |
1A1E:0B | SubIndex 011 | 11. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x0B (Power Quality Guard Warning)) | UINT32 | RO | 0xF600:0B, 1 |
1A1E:0C | SubIndex 012 | 12. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x0C (Power Quality Guard Error)) | UINT32 | RO | 0xF600:0C, 1 |
1A1E:0D | SubIndex 013 | 13. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1A1E:0E | SubIndex 014 | 14. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x0F (TxPDO State)) | UINT32 | RO | 0xF600:0F, 1 |
1A1E:0F | SubIndex 015 | 15. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0xF600:10, 1 |
1A1E:10 | SubIndex 016 | 16. PDO Mapping entry (object 0xF600 (PMX Total Status), entry 0x11 (Power Quality Factor)) | UINT32 | RO | 0xF600:11, 32 |
Index 1A20 Total TxPDO-Map Total Advanced
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A20:0 | Total TxPDO-Map Total Advanced | PDO Mapping TxPDO | UINT8 | RO | 0x03 (3dec) |
1A20:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF602 (PMX Total Advanced), entry 0x01 (Unbalance Guard Warning)) | UINT32 | RO | 0xF602:01, 1 |
1A20:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF602 (PMX Total Advanced), entry 0x02 (Unbalance Guard Error)) | UINT32 | RO | 0xF602:02, 1 |
1A20:03 | SubIndex 003 | 3. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
Index 1A21 Total TxPDO-Map Total Active
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A21:0 | Total TxPDO-Map Total Active | PDO Mapping TxPDO | UINT8 | RO | 0x04 (4dec) |
1A21:01 | SubIndex 001 | 1. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A21:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF603 (PMX Total Active), entry 0x12 (Active Energy)) | UINT32 | RO | 0xF603:12, 64 |
1A21:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF603 (PMX Total Active), entry 0x13 (Active Positive Energy)) | UINT32 | RO | 0xF603:13, 64 |
1A21:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF603 (PMX Total Active), entry 0x14 (Active Negative Energy)) | UINT32 | RO | 0xF603:14, 64 |
Index 1A22 Total TxPDO-Map Total Apparent
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A22:0 | Total TxPDO-Map Total Apparent | PDO Mapping TxPDO | UINT8 | RO | 0x04 (4dec) |
1A22:01 | SubIndex 001 | 1. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A22:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF605 (PMX Total Apparent), entry 0x12 (Apparent Energy)) | UINT32 | RO | 0xF605:12, 64 |
1A22:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF605 (PMX Total Apparent), entry 0x13 (Apparent Positive Energy)) | UINT32 | RO | 0xF605:13, 64 |
1A22:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF605 (PMX Total Apparent), entry 0x14 (Apparent Negative Energy)) | UINT32 | RO | 0xF605:14, 64 |
Index 1A23 Total TxPDO-Map Total Reactive
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A23:0 | Total TxPDO-Map Total Reactive | PDO Mapping TxPDO | UINT8 | RO | 0x04 (4dec) |
1A23:01 | SubIndex 001 | 1. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A23:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF607 (PMX Total Reactive), entry 0x12 (Reactive Energy)) | UINT32 | RO | 0xF607:12, 64 |
1A23:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF607 (PMX Total Reactive), entry 0x13 (Reactive Positive Energy)) | UINT32 | RO | 0xF607:13, 64 |
1A23:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF607 (PMX Total Reactive), entry 0x14 (Reactive Negative Energy)) | UINT32 | RO | 0xF607:14, 64 |
Index 1A26 Total TxPDO-Map Total Statistic Power
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A26:0 | Total TxPDO-Map Total Statistic Power | PDO Mapping TxPDO | UINT8 | RO | 0x09 (9dec) |
1A26:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x11 (Active Power Avg)) | UINT32 | RO | 0xF60B:11, 32 |
1A26:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x12 (Active Power Min)) | UINT32 | RO | 0xF60B:12, 32 |
1A26:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x13 (Active Power Max)) | UINT32 | RO | 0xF60B:13, 32 |
1A26:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x14 (Apparent Power Avg)) | UINT32 | RO | 0xF60B:14, 32 |
1A26:05 | SubIndex 005 | 5. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x15 (Apparent Power Min)) | UINT32 | RO | 0xF60B:15, 32 |
1A26:06 | SubIndex 006 | 6. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x16 (Apparent Power Max)) | UINT32 | RO | 0xF60B:16, 32 |
1A26:07 | SubIndex 007 | 7. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x17 (Reactive Power Avg)) | UINT32 | RO | 0xF60B:17, 32 |
1A26:08 | SubIndex 008 | 8. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x18 (Reactive Power Min)) | UINT32 | RO | 0xF60B:18, 32 |
1A26:09 | SubIndex 009 | 9. PDO Mapping entry (object 0xF60B (PMX Total Statistic Power), entry 0x19 (Reactive Power Max)) | UINT32 | RO | 0xF60B:19, 32 |
Index 1A27 Total TxPDO-Map Total Statistic PQF
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A27:0 | Total TxPDO-Map Total Statistic PQF | PDO Mapping TxPDO | UINT8 | RO | 0x03 (3dec) |
1A27:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF60C (PMX Total Statistic PQF), entry 0x11 (PQF Avg)) | UINT32 | RO | 0xF60C:11, 32 |
1A27:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF60C (PMX Total Statistic PQF), entry 0x12 (PQF Min)) | UINT32 | RO | 0xF60C:12, 32 |
1A27:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF60C (PMX Total Statistic PQF), entry 0x13 (PQF Max)) | UINT32 | RO | 0xF60C:13, 32 |
Index 1A28 Total TxPDO-Map Total Interval Energy
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A28:0 | Total TxPDO-Map Total Interval Energy | PDO Mapping TxPDO | UINT8 | RO | 0x0B (11dec) |
1A28:01 | SubIndex 001 | 1. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
1A28:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0xF60D:10, 1 |
1A28:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x11 (Active Energy)) | UINT32 | RO | 0xF60D:11, 32 |
1A28:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x12 (Active Energy Positive)) | UINT32 | RO | 0xF60D:12, 32 |
1A28:05 | SubIndex 005 | 5. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x13 (Active Energy Negative)) | UINT32 | RO | 0xF60D:13, 32 |
1A28:06 | SubIndex 006 | 6. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x14 (Apparent Energy)) | UINT32 | RO | 0xF60D:14, 32 |
1A28:07 | SubIndex 007 | 7. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x15 (Apparent Energy Positive)) | UINT32 | RO | 0xF60D:15, 32 |
1A28:08 | SubIndex 008 | 8. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x16 (Apparent Energy Negative)) | UINT32 | RO | 0xF60D:16, 32 |
1A28:09 | SubIndex 009 | 9. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x17 (Reactive Energy)) | UINT32 | RO | 0xF60D:17, 32 |
1A28:0A | SubIndex 010 | 10. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x18 (Reactive Energy Positive)) | UINT32 | RO | 0xF60D:18, 32 |
1A28:0B | SubIndex 011 | 11. PDO Mapping entry (object 0xF60D (PMX Total Interval Energy), entry 0x19 (Reactive Energy Negative)) | UINT32 | RO | 0xF60D:19, 32 |
Index 1A29 Total TxPDO-Map Active Reduced
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A29:0 | Total TxPDO-Map Active Reduced | PDO Mapping TxPDO | UINT8 | RO | 0x02 (2dec) |
1A29:01 | SubIndex 001 | 1. PDO Mapping entry (Aligned)) | UINT32 | RO | 0x0000:00, 32 |
1A29:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF612 (PMX Total Active Reduced entry 0x12 (Active Energy)) | UINT32 | RO | 0xF612:12, 64 |
Index 1A2A Total TxPDO-Map Apparent Reduced
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A2A:0 | Total TxPDO-Map Apparent Reduced | PDO Mapping TxPDO | UINT8 | RO | 0x02 (2dec) |
1A2A:01 | SubIndex 001 | 1. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A2A:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF613 (PMX Total Apparent Reduced), entry 0x12 (Apparent Energy)) | UINT32 | RO | 0xF613:12, 64 |
Index 1A2B Total TxPDO-Map Reactive Reduced
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A2B:0 | Total TxPDO-Map Reactive Reduced | PDO Mapping TxPDO | UINT8 | RO | 0x02 (2dec) |
1A2B:01 | SubIndex 001 | 1. PDO Mapping entry (32 bits align) | UINT32 | RO | 0x0000:00, 32 |
1A2B:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF614 (PMX Total Reactive Reduced), entry 0x12 (Reactive Energy)) | UINT32 | RO | 0xF614:12, 64 |
Index 1A2C Total TxPDO-Map Interval Energy Reduced
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A2C:0 | Total TxPDO-Map Interval Energy Reduced | PDO Mapping TxPDO | UINT8 | RO | 0x05 (5dec) |
1A2C:01 | SubIndex 001 | 1. PDO Mapping entry (align) | UINT32 | RO | 0x0000:00, 15 |
1A2C:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF615 (PMX Total Interval Energy Reduced), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0xF615:10, 1 |
1A2C:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF615 (PMX Total Interval Energy Reduced), entry 0x11 (Active Energy)) | UINT32 | RO | 0xF615:11, 32 |
1A2C:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF615 (PMX Total Interval Energy Reduced), entry 0x12 (Apparent Energy)) | UINT32 | RO | 0xF615:12, 32 |
1A2C:05 | SubIndex 005 | 5. PDO Mapping entry (object 0xF615 (PMX Total Interval Energy Reduced), entry 0x13 (reactive Energy)) | UINT32 | RO | 0xF615:13, 32 |
Index 1C00 Sync manager type
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C00:0 | Sync manager type | Length of this object | UINT8 | RO | 0x04 (4dec) |
1C00:01 | SubIndex 001 | Sync-Manager Type Channel 1: Mailbox Write | UINT8 | RW | 0x01 (1dec) |
1C00:02 | SubIndex 002 | Sync-Manager Type Channel 2: Mailbox Read | UINT8 | RW | 0x02 (2dec) |
1C00:03 | SubIndex 003 | Sync-Manager Type Channel 3: Process Data Write (Outputs) | UINT8 | RW | 0x03 (3dec) |
1C00:04 | SubIndex 004 | Sync-Manager Type Channel 4: Process Data Read (Inputs) | UINT8 | RW | 0x04 (4dec) |
Index 1C12 RxPDO assign
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C12:0 | RxPDO assign | PDO Assign Outputs | UINT8 | RW | 0x01 (1dec) |
1C12:01 | SubIndex 001 | 1. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1601 (5633dec) |
Index 1C13 TxPDO assign
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C13:0 | TxPDO assign | PDO Assign Inputs | UINT8 | RW | 0x0B (11dec) |
1C13:01 | SubIndex 001 | 1. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A00 (6656dec) |
1C13:02 | SubIndex 002 | 2. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A0A (6666dec) |
1C13:03 | SubIndex 003 | 3. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A14 (6676dec) |
1C13:04 | SubIndex 004 | 4. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A1E (6686dec) |
1C13:05 | SubIndex 005 | 5. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A20 (6688dec) |
1C13:06 | SubIndex 006 | 6. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A26 (6694dec) |
1C13:07 | SubIndex 007 | 7. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A27 (6695dec) |
1C13:08 | SubIndex 008 | 8. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A29 (6697dec) |
1C13:09 | SubIndex 009 | 9. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A2A (6698dec) |
1C13:0A | SubIndex 010 | 10. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A2B (6699dec) |
1C13:0B | SubIndex 011 | 11. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A2C (6700dec) |
1C13:0C | SubIndex 012 | 12. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
… |
|
|
|
|
|
1C13:1B | SubIndex 027 | 27. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
Index 1C32 SM output parameter
Index | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C32:0 | SM output parameter | Synchronization parameters for the outputs | UINT8 | RO | 0x20 (32dec) |
1C32:01 | Sync mode | Current synchronization mode: 0: Free Run 1: Synchron with SM 2 Event 2: DC-Mode - Synchron with SYNC0 Event 3: DC-Mode - Synchron with SYNC1 Event | UINT16 | RW | 0x0000 (0dec) |
1C32:02 | Cycle time | Cycle time (in ns): Free Run: cycle time of the local timer Synchron with SM 2 Event: cycle time of the master DC-Mode: SYNC0/SYNC1 Cycle Time | UINT32 | RW | 0x0016E360 (1500000dec) |
1C32:03 | Shift time | Time between SYNC0 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C32:04 | Sync modes supported | Sync modes supported: Bit 0 = 1: Free Run is supported Bit 1 = 1: Synchron with SM 2 Event is supported Bit 2-3 = 01: DC-Mode is supported Bit 4-5 = 10: Output Shift with SYNC1 Event (DC mode only) Bit 14 = 1: dynamic times (measurement through writing of 1C32:08) | UINT16 | RO | 0x0805 (2053dec) |
1C32:05 | Minimum cycle time | Minimum cycle time (in ns) | UINT32 | RO | 0x0007A120 (500000dec) |
1C32:06 | Calc and copy time | Minimum time between SYNC0 and SYNC1 event (in ns, DC Mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C32:07 | Minimum delay time | Minimum time between SYNC1 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C32:08 | Command | 0: Measurement of the local cycle time is stopped 1: Measurement of the local cycle time is started The entries 1C32:03, 1C32:05, 1C32:06, 1C32:09, 1C33:03, 1C33:06, 1C33:09 are updated with the maximum measured values. | UINT16 | RW | 0x0000 (0dec) |
1C32:09 | Maximum delay time | Time between SYNC1 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C32:0B | SM event missed counter | Number of missed SM events in OPERATIONAL (DC Mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:0C | Cycle exceeded counter | Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early) | UINT16 | RO | 0x0000 (0dec) |
1C32:0D | Shift too short counter | Number of intervals between SYNC0 and SYNC1 events that are too short (DC Mode only) | UINT16 | RO | 0x0000 (0dec) |
Index 1C33 SM input parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C33:0 | SM input parameter | Synchronization parameters for the inputs | UINT8 | RO | 0x20 (32dec) |
1C33:01 | Sync mode | Current synchronization mode: 0: Free Run 1: Synchron with SM 3 Event (no outputs available) 2: DC - Synchron with SYNC0 Event 3: DC - Synchron with SYNC1 Event 34: Synchron with SM 2 Event (outputs available) | UINT16 | RW | 0x0000 (0dec) |
1C33:02 | Cycle time | as 1C32:02 | UINT32 | RW | 0x0016E360 (1500000dec) |
1C33:03 | Shift time | Time between SYNC0 event and reading of the inputs (in ns, DC Mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C33:04 | Sync modes supported | Sync modes supported: Bit 0: Free Run is supported Bit 1: Synchron with SM 2 Event is supported (outputs available) Bit 1: Synchron with SM 3 Event is supported (no outputs available) Bit 2-3 = 01: DC-Mode is supported Bit 4-5 = 01: Input shift through local event (outputs available) Bit 4-5 = 10: Input shift with SYNC1 event (no outputs available) Bit 14 = 1: dynamic times (measurement through writing of 1C32:08 or 1C33:08) | UINT16 | RO | 0x0805 (2053dec) |
1C33:05 | Minimum cycle time | as 1C32:05 | UINT32 | RO | 0x0007A120 (500000dec) |
1C33:06 | Calc and copy time | Time between reading of the inputs and the inputs being available for the master (in ns, DC Mode only) | UINT32 | RO | 0x0007A120 (500000dec) |
1C33:07 | Minimum delay time | Minimum time between SYNC1 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C33:08 | Command | as 1C32:08 | UINT16 | RW | 0x0000 (0dec) |
1C33:09 | Maximum delay time | Time between SYNC1 event and reading of the inputs (in ns, DC Mode only) | UINT32 | RO | 0x00000384 (900dec) |
1C33:0B | SM event missed counter | as 1C32:11 | UINT16 | RO | 0x0000 (0dec) |
1C33:0C | Cycle exceeded counter | as 1C32:12 | UINT16 | RO | 0x0000 (0dec) |
1C33:0D | Shift too short counter | as 1C32:13 | UINT16 | RO | 0x0000 (0dec) |
Index F000 Modular device profile
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F000:0 | Modular device profile | Largest subindex of this object | UINT8 | RO | 0x02 (2dec) |
F000:01 | Module index distance | Index distance of the objects of the individual channels | UINT16 | RW | 0x0010 (16dec) |
F000:02 | Maximum number of modules | Number of channels | UINT16 | RW | 0x0003 (3dec) |
Index F008 Code word
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F008:0 | Code word | reserved | UINT32 | RW | 0x00000000 (0dec) |
![]() | Code Word The vendor reserves the authority for the basic calibration of the terminals. The code word is therefore at present reserved. |
