EL3483 - Technical data

Analog specifications

EL3483-0000

EL3483-0060

Number of inputs

3 x voltage

Technology

3-phase mains monitor

Special features

operation as voltage monitor, frequency monitor and phase monitor also possible in single-phase operation

Oversampling factor

–

Update interval

ten mains periods (200 ms at 50 Hz)

Internal sampling rate

approx. 9.7 ksps (per channel)

Sampling type

simultaneously across all channels

Ground reference

single-ended

Update time

mains-synchronous

Monitoring function

phase sequence, phase failure, phase imbalance, undervoltage/overvoltage (adjustable)

Parameters measured

EL3483-0000

EL3483-0060

Measured values

digital thresholds and power quality factor (PowerQualityFactor)

digital thresholds and power quality factor (PowerQualityFactor),
analog voltage measurement

Measuring voltage

max. 480 V AC 3~ (ULX-N: max. 277 V AC; max. 240 V DC)

Measuring procedure

true RMS value calculation

Supply and potentials

EL3483-0000

EL3483-0060

Electrical isolation

2500 V

Current consumption Power contacts

–

Current consumption via E-bus

120 mA typ.

Communication

EL3483-0000

EL3483-0060

Configuration

via TwinCAT System Manager

Distributed clocks

–

Environmental conditions

EL3483-0000

EL3483-0060

Permissible ambient temperature range during operation

-25 °C ... +60 °C

Permissible ambient temperature range during storage

-40 °C ... +85 °C

Relative humidity

95 %, no condensation

General data

EL3483-0000

EL3483-0060

Weight

approx. 75 g

Dimensions (W x H x D)

approx. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)

Installation

on 35 mm mounting rail, conforms to EN 60715

Installation position

variable

Standards and approvals

EL3483-0000

EL3483-0060

Vibration/shock resistance

conforms to EN 60068-2-6 / EN 60068-2-27

EMC immunity/emission

conforms to EN 61000-6-2 / EN 61000-6-4

Protection rating

IP20

Marking/certification*)

CE, EAC, UKCA
cULus,

*) Real applicable approvals/markings see type plate on the side (product marking).