Information and diagnostic data
Index 800E AI Internal data bridge
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
800E:0 |
AI Internal data bridge |
Maximum subindex |
UINT8 |
RO |
0x01 (1dec) |
|
800E:01 |
ADC raw value |
ADC raw value |
UINT32 |
RO |
0x00000000 (0dec) |
Index 801E AI Internal data supply
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
801E:0 |
AI Internal data supply |
Maximum subindex |
UINT8 |
RO |
0x01 (1dec) |
|
801E:01 |
ADC raw value |
ADC raw value |
UINT32 |
RO |
0x00000000 (0dec) |
Index F000 Modular device profile
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F000:0 |
Modular device profile |
General information for the modular device profile |
UINT8 |
RO |
0x02 (2dec) |
|
F000:01 |
Module index distance |
Index spacing of the objects of the individual channels |
UINT16 |
RO |
0x0010 (16dec) |
|
F000:02 |
Maximum number of modules |
Number of channels |
UINT16 |
RO |
0x0002 (2dec) |
Index F008 Code word
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F008:0 |
Code word |
currently reserved |
UINT32 |
RW |
0x00000000 (0dec) |
Index F010 Module list
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F010:0 |
Module list |
Maximum subindex |
UINT8 |
RW |
0x02 (2dec) |
|
F010:01 |
SubIndex 001 |
reserved |
UINT32 |
RW |
0x0000012C (300dec) |
|
F010:02 |
SubIndex 002 |
reserved |
UINT32 |
RW |
0x0000012C (300dec) |