Configuration data (vendor-specific)

Index 800F AI Vendor data bridge

Index (hex)

Name

Meaning

Data type

Flags

Default

800F:0

AI Vendor data bridge

Maximum subindex

UINT8

RO

0x03 (3dec)

800F:01

Calibration offset

Offset (vendor calibration)

INT32

RW

0x00000000 (0dec)

800F:02

Calibration gain pos

Gain pos. (vendor calibration)

UINT32 

RW 

0x00944000 (9715712dec) 

800F:03

Calibration gain neg. 

Gain neg. (vendor calibration)

UINT32

RW

0x00944000 (9715712dec)

Index 801F AI Vendor data supply

Index (hex)

Name

Meaning

Data type

Flags

Default

801F:0

AI Vendor data supply

Maximum subindex

UINT8

RO

0x03 (3dec)

801F:01

Calibration offset

Offset (vendor calibration)

INT32

RW

0x00000000 (0dec)

801F:02

Calibration gain pos

Gain pos. (vendor calibration)

UINT32 

RW 

0x00944000 (9715712dec) 

801F:03

Calibration gain neg. 

Gain neg. (vendor calibration)

UINT32

RW

0x00944000 (9715712dec)