Firmware compatibility

Beckhoff EtherCAT devices are delivered with the latest available firmware version. Firmware and hardware must be compatible; not every combination ensures compatibility. The overview below shows the hardware versions on which a firmware can be operated.

Note

Notice

Risk of damage to the device!

Observe the notes on the firmware update in the EtherCAT System Manual in chapter “Firmware Update”.
If a device is set to BOOTSTRAP mode for firmware update, it may not check whether the new firmware is suitable during download.
This may result in damage to the device! Therefore, always make sure that the firmware is suitable for the hardware version!

EL3201

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 02

03

EL3201-0000-0016

2008/03

04

 

2009/04

05

 

2009/05

02

06

EL3201-0000-0017

2010/04

03 - 14*

07*

 

2010/06

EL3201-0000-0018

2012/06

EL3201-0000-0019

2012/07

EL3201-0000-0020

2014/07

EL3201-0000-0021

2015/01

EL3201-0000-0022

2016/01

EL3201-0010

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 02

03

EL3201-0010-0016

2008/11

04

 

2009/04

05

 

2009/05

02

06

EL3201-0010-0017

2010/04

03 - 13*

07*

 

2010/06

EL3201-0010-0018

2012/06

EL3201-0010-0019

2012/07

EL3201-0010-0020

2014/07

EL3201-0010-0021

2015/01

EL3201-0010-0022

2016/02

EL3201-0020

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 02

03

EL3201-0020-0016

2008/11

04

 

2009/04

05

 

2009/05

02

06

EL3201-0020-0017

2010/04

03 - 14*

07*

 

2010/06

EL3201-0020-0018

2012/06

EL3201-0020-0019

2012/07

EL3201-0020-0020

2014/07

EL3201-0020-0021

2015/01

EL3201-0020-0022

2016/02

EL3202

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 02

03

EL3202-0000-0016

2008/03

04

 

2009/04

05

 

2009/05

03 - 15*

06

EL3202-0000-0017

2010/04

07*

 

2010/06

EL3202-0000-0018

2012/06

EL3202-0000-0019

2012/07

EL3202-0000-0020

2014/07

EL3202-0000-0021

2015/01

EL3202-0000-0022

2016/01

EL3202-0010

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 01

05

EL3202-0010-0016

2009/07

06

EL3202-0010-0017

2010/04

01 - 12*

07

 

2010/06

08

 

2010/10

09

 

2011/07

10

 

2011/09

EL3202-0010-0018

2012/06

EL3202-0010-0019

2012/07

EL3202-0010-0020

2014/07

EL3202-0010-0021

2015/01

EL3202-0010-0022

2016/01

11*

 

2021/07

EL3202-0020

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

01 - 12*

09

EL3202-0020-0017

2011/02

10

 

2011/09

EL3202-0020-0018

2012/06

EL3202-0020-0019

2012/07

EL3202-0020-0020

2014/07

EL3202-0020-0021

2015/01

EL3202-0020-0022

2016/01

11*

 

2021/07

EL3204

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 02

03

EL3204-0000-0016

2008/03

04

 

2009/04

05

 

2009/05

03 - 12

06

EL3204-0000-0017

2010/04

07

 

2011/06

EL3204-0000-0018

2012/07

EL3204-0000-0019

2014/07

EL3204-0000-0020

2015/01

EL3204-0000-0021

2016/01

13 – 16*

10

EL3204-0000-0022

2022/08

EL3204-0200

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 06*

01

EL3204-0200-0016

2013/08

02*

EL3204-0200-0017

2014/04

EL3204-0200-0018

2016/02

EL3208

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 06

01

EL3208-0000-0017

2014/04

EL3208-0000-0018

2016/02

08*

10*

EL3208-0000-0019

2023/06

EL3208-0010

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 - 06*

01

EL3208-0010-0016

2018/09

02

 

2023/05

03*

 

2026/04

EL3214

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 – 03

01

EL3214-0000-0016

2015/01

EL3214-0000-0017

2017/06

01

02

 

2020/11

05 – 08

10

EL3214-0000-0018

2023/06

04 – 08*

11*

 

2024/11

EL3214-0090

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

00 – 04

01

EL3214-0090-0016

2017/02

02

 

2018/09

05 – 08*

10*

EL3214-0090-0017

2024/07

EL3218

Hardware (HW)

Firmware (FW)

Revision no.

Date of release

01 – 02*

01

EL3218-0000-0016

2020/02

02

EL3218-0000-0017

2021/07

03*

 

2025/04

*) This is the current compatible firmware/hardware version at the time of the preparing this documentation. Check on the Beckhoff website whether more up-to-date documentation is available.