Technical data

Device functions

EL2574

Application recommendation

Control of individually addressable LEDs

Number of outputs

4

Input voltage

5…24 VDC

Power supply LED

  • External
  • or via the terminal points "Ext. 5...24 V" and "GND" with the following restrictions (applies to HW < 02):
    • > 50°C ambient temperature: no supply via terminal
    • 45...50°C ambient temperature: with 3 A supply
    • < 45°C ambient temperature: with 6 A supply
    • With ZB8610 8 A: supply over the entire temperature range.

LED protocol

WS2801, WS2803, WS2811, WS2812, WS2812B, WS2813, WS2815, WS2818, APA-101, APA102, APA-104, APA-109, CS8812, GS8206, GS8208, INK1002, INK1003, SK6812, SK6813, SK6822, SM16703, SM16704, TM1803, TM1804, TM1809, TM1812, TM1814, UCS1903, UCS1912, UCS2903, UCS2912, UCS2904, GE8822, HD107S, SK9822

Number of pixels

2048 pixels per terminal

Supply of the internal electronics

24 V via power contacts

Communication

EL2574

Configuration

via TwinCAT System Manager

Distributed Clocks

–

General data

EL2574

Current consumption via E-bus

80 mA typ.

Weight

approx. 50 g

Dimensions

approx. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)

Mounting

on 35 mm mounting rail, conforms to EN 60715

Installation position

variable

Environmental conditions

EL2574

Permissible ambient temperature range during operation

0°C ... +55°C
-25°C ... +60°C (from HW02)

Permissible ambient temperature range during storage

-25°C ... +85°C

Permissible relative air humidity

95%, no condensation

Standards and approvals

EL2574

Vibration / shock resistance

conforms to EN 60068-2-6 / EN 60068-2-27

EMC immunity / emission

conforms to EN 61000-6-2 / EN 61000-6-4

Protection rating

IP20

Approvals/markings*)

CE

*) Real applicable approvals/markings see type plate on the side (product marking).