EL252x - when using the predefined PDO Assignments "n Ch Standard 16 Bit (MDP 253/511)"
The links from Axis/Drive/nOutData5 to the "Target Counter Value" of the terminal are not automatically created in the operation modes "n Ch Standard 16 Bit".
Create the link from Axis/Drive/nOutData5 to the "Target Counter Value" of the terminal.
- To do this, right-click on Target counter value and
- select "Change link..." (see fig. Change link).
- In the dialog Variable linking, select the variable Axis/Drive/nOutData5 and confirm with OK (see A and B in fig. Creating a link from Axis/Drive/nOutData5 to Target Counter Value).
- The coverage of 16 bits is confirmed in the subsequent dialog Variable size difference. Confirm with OK (see C in fig. Creating a link from Axis/Drive/nOutData5 to Target Counter Value).