Connection of the EL2522 in the NC
![]() | Required Firmware (FW) Version and TwinCAT Version At least FW Version 07 is required for Connection of terminal EL2522 to the NC; TwinCAT-Versions: |
Procedure
When EL2522 terminal was added to TwinCAT-IO, the procedure is as follows:
1. Select a specific EL2522 operating mode

2. Link the non-referenced axes to the terminal
a)

b)

3. Set distributed clock: “DC-Synchron” on “DC” tab

4. Set the frequency of the terminal in order to achieve the required velocity.

When using no up to date FW or rather not up dated TwinCAT versions, accordingly to the “Continues Position” Mode the following should be noticed, if applicable:
- Update the NC driver
- Add axis to the NC
As soon as (between step 2. And 3.):
- Link Axis/Drive/nOutData5 to the “Target counter value” of the terminal
a)

b)

- Link Axis/Drive/nCtrl1 to “Automatic direction” of the terminal
a)

b)

c)