0x14xx | Excluded RxPDOs
Index 1400 PWM RxPDO-Par Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1400:0 | RxPDO-Par Outputs Ch.1 | PDO Parameter Outputs Ch.1 | UINT8 | RO | 0x06 (6dec) |
1400:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 01 16 02 16 03 16 |
Index 1401 PWM RxPDO-Par Per. Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1401:0 | RxPDO-Par Per. Outputs Ch.1 | PDO Parameter Per. Outputs Ch.1 | UINT8 | RO | 0x06 (6dec) |
1401:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 00 16 02 16 03 16 |
Index 1402 PWM RxPDO-Par DC Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1402:0 | RxPDO-Par DC Outputs Ch.1 | PDO Parameter DC Outputs Ch.1 | UINT8 | RO | 0x06 (6dec) |
1402:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 00 16 01 16 03 16 |
Index 1403 PWM RxPDO-Par Per, DC Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1403:0 | RxPDO-Par Per, DC Outputs Ch.1 | PDO Parameter Per, DC Outputs Ch.1 | UINT8 | RO | 0x06 (6dec) |
1403:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 00 16 01 16 02 16 |
Index 1404 PWM RxPDO-Par Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1404:0 | RxPDO-Par Outputs Ch.2 | PDO Parameter Outputs Ch.2 | UINT8 | RO | 0x06 (6dec) |
1404:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 05 16 06 16 07 16 |
Index 1405 PWM RxPDO-Par Per. Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1405:0 | RxPDO-Par Per. Outputs Ch.2 | PDO Parameter Per. Outputs Ch.2 | UINT8 | RO | 0x06 (6dec) |
1405:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 04 16 06 16 07 16 |
Index 1406 PWM RxPDO-Par DC Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1406:0 | RxPDO-Par DC Outputs Ch.2 | PDO Parameter DC Outputs Ch.2 | UINT8 | RO | 0x06 (6dec) |
1406:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 04 16 05 16 07 16 |
Index 1407 PWM RxPDO-Par Per, DC Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1407:0 | RxPDO-Par Per, DC Outputs Ch.2 | PDO Parameter Per, DC Outputs Ch.2 | UINT8 | RO | 0x06 (6dec) |
1407:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with this RxPDO | OCTET-STRING[2] | RO | 04 16 05 16 06 16 |