Status Byte
The first two bits of the status byte for each channel indicate whether a rising or falling edge has been detected or latched. The other bits are intended for future purpose and shall not be evaluated.
Bit | SB.7 | SB.6 | SB.5 | SB.4 | SB.3 | SB.2 | SB.1 | SB.0 |
Name | Reserved | Reserved | Reserved | Reserved | Reserved | Reserved | Event falling | Event rising |
The flags will signal only, if the terminal selected in the system tree is set to “Single Event” instead of “Continuous” under
„EtherCAT→Advanced Settings“: Distributed Clock/ Latch for the relevant event:

The flags are not reset until the respective LatchPosXXXY variables are then read.
![]() | Performance Please be sure that the technical possibilities offered by the EL1252/EL1254 are exploited fully by providing high input signal quality, avoiding contact bounce and line interference, and by providing an input signal with sufficiently short rise and fall times! |