Technical data
All values are typical values over the entire temperature range, unless stated otherwise.
Inputs and outputs | |
|---|---|
Inputs | 2 x end position |
Outputs | 1 x BLDC motor |
E-bus | |
|---|---|
Electrical isolation | 500 V (E-bus/field voltage) |
Distributed Clocks | yes |
Current consumption via E-bus | typ. 120 mA |
Supply voltages | |
|---|---|
Electronics supply voltage | 24 VDC (via distribution board) |
Current consumption from the Up contacts | 50 mA typ. + holding current for the motor brake |
Current load Up contacts | Current carrying capacity per pin: 3 A |
Supply voltage power | 8 VDC … 48 VDC (via distribution board) |
Motor output stage | |
|---|---|
Motor type | BLDC motor |
Connection technology | Direct motor connection + feedback |
Load type | DC motor |
Minimum winding inductance | 200 µH |
Number of channels | 1 |
Output current (rms) | 4.5 A (rms) |
Peak current (rms) | max. 9.0 A (rms) for 1 second |
Rotary field frequency | 0 … 599 Hz |
PWM clock frequency | 16 kHz |
Current controller frequency | 32 kHz |
Output for the motor brake | |
|---|---|
Output voltage | 24 VDC |
Output current | max. 0.5 A |
Encoder | |
|---|---|
Encoder type | Incremental encoders |
Signal types | RS422, TTL, HTL, Open collector |
Maximum input frequency | depending on signal type: (see chapter Configuration of the incremental encoder) |
Supply voltage output for encoder | 2 VDC ... 24 VDC, adjustable (factory setting: 5 VDC)
max. 300 mA short-circuit proof |
Hall sensors | |
|---|---|
Signal type | Open Collector |
Supply voltage output for Hall sensors | 2 VDC ... 24 VDC, adjustable (factory setting: 5 VDC)
max. 300 mA short-circuit proof |
Environmental conditions | |
|---|---|
Ambient temperature during operation | 0 °C … +55 °C |
Ambient temperature during storage | -25 °C … +85 °C |
Relative humidity | 95 % no condensation |
Degree of pollution | 2 |
Operating altitude | max. 2,000 m |
Vibration/shock resistance | conforms to EN 60068-2-6 /EN 60068-2-27 (with corresponding signal distribution board) |
EMC immunity/emission | conforms to EN 61000-6-2 /EN 61000-6-4 (with corresponding signal distribution board) |
EMC category | Category C3 - standard |
Protection rating | EJ module: IP20 |
Housing data | |
|---|---|
Design | EtherCAT I/O plug-in module |
1 and 8 | |
Color coding | orange |
Weight | approx. 50 g |
Installation position | |
Material | polycarbonate |
Dimensions (W x H x D) | approx. 24 mm x 66 mm x 55 mm |
Mounting | On signal distribution board |
Approvals and conformity | |
|---|---|
Approvals/markings* | CE, UKCA |
*) Real applicable approvals/markings see type plate on the side (product marking).
![]() | CE approval The CE Marking refers to the EtherCAT plug‑in module mentioned above. |