Information and diagnostic data

Index 10F3 Diagnosis History

Index (hex)

Name

Meaning

Data type

Flags

Default

10F3:0

Diagnosis History

Max. Subindex

UINT8

RO

0x37 (55dec)

10F3:01

Maximum Messages

Maximum number of stored messages.
A maximum of 50 messages can be stored

UINT8

RO

0x00 (0dec)

10F3:02

Newest Message

Subindex of the latest message

UINT8

RO

0x00 0dec)

10F3:03

Newest Acknowledged Message

Subindex of the last confirmed message

UINT8

RO

0x00 (0dec)

10F3:04

New Message available

Indicates that a new message is available

BOOLEAN

RO

0x00 (0dec)

10F3:05

Flags

not used

UINT16

RO

0x0000 (0dec)

10F3:06

Diagnosis Message 001

Message 1

OCTET-STRING[28]

RO

{0}

…

…

…

…

…

…

10F3:37

Diagnosis Message 050

Message 50

OCTET-STRING[28]

RO

{0}

Index 10F8 Actual Time Stamp

Index (hex)

Name

Meaning

Data type

Flags

Default

10F8:0

Actual Time Stamp

Timestamp

UINT64

RO

 

Index 9001 LIC Identity Data

Index (hex)

Name

Meaning

Data type

Flags

Default

9001:0

LIC Identity Data

Max. subindex

UINT8

RO

0x05 (5dec)

9001:01

Public Key

reserved

OCTET-STRING[256]

RO

-

9001:02

Certificate

reserved

OCTET-STRING[256]

RO

-

9001:03

Public EK

reserved

OCTET-STRING[256]

RO

-

9001:04

Certificate EK

reserved

OCTET-STRING[256]

RO

-

9001:05

Volume Number

reserved

UINT32

RO

0x00000000 (0dec)

Index 9002 LIC Session Data

Index (hex)

Name

Meaning

Data type

Flags

Default

9002:0

LIC Session Data

Max. Subindex

UINT8

RO

0x04 (4dec)

9002:01

Signature

reserved

OCTET-STRING[256]

RO

{0}

9002:02

PCR Value

reserved

OCTET-STRING[20]

RO

{0}

9002:03

Tick Stamp

reserved

OCTET-STRING[256]

RO

{0}

9002:04

Current Ticks

reserved

OCTET-STRING[30]

RO

{0}

Index B008 LIC Control

Index (hex)

Name

Meaning

Data type

Flags

Default

B008:0

LIC Control

Max. Subindex

UINT8

RO

0x03 (3dec)

B008:01

Control

reserved

UINT16

RW

0x0000 (0dec)

B008:02

Status

reserved

UINT16

RO

0x0000 (0dec)

B008:03

Challenge

reserved

OCTET-STRING[20]

RW

{0}

Index F900 LIC Time Data

Index (hex)

Name

Meaning

Data type

Flags

Default

F900:0

LIC Time Data

Max. subindex

UINT8

RO

0x01 (1dec)

F900:01

Operating Time

Non-erasable operating hours counter
[s]

UINT32

RO

0x00000000 (0dec)

Index FB40 Memory interface

Index (hex)

Name

Meaning

Data type

Flags

Default

FB40:0

Memory interface

Maximum subindex

UINT8

RO

0x03 (3dec)

FB40:01

Address

reserved

UINT32

RW

0x00000000 (0dec)

FB40:02

Length

reserved

UINT16

RW

0x0000 (0dec)

FB40:03

Data

reserved

OCTET-STRING[8]

RW

{0}