Profile-specific objects
Index 6000 FB Inputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
6000:0 |
FB Inputs Ch.1 |
|
UINT8 |
RO |
0x15 (21dec) |
|
6000:0E |
TxPDO State |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6000:0F |
Input cycle counter |
|
BIT2 |
RO |
0x00 (0dec) |
|
6000:11 |
Position |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6000:15 |
Secondary position |
|
UINT32 |
RO |
0x00000000 (0dec) |
Index 6001 FB Touch probe inputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
6001:0 |
FB Touch probe inputs Ch.1 |
|
UINT8 |
RO |
0x18 (24dec) |
|
6001:01 |
TP1 Enable |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:02 |
TP1 Pos value stored |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:03 |
TP1 Neg value stored |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:08 |
TP1 Input |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:09 |
TP2 Enable |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:0A |
TP2 Pos value stored |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:0B |
TP2 Neg value stored |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:10 |
TP2 Input |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6001:11 |
TP1 Pos position |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:12 |
TP1 Neg position |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:13 |
TP2 Pos position |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:14 |
TP2 Neg position |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:15 |
TP1 Pos timestamp |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:16 |
TP1 Neg timestamp |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:17 |
TP2 Pos timestamp |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6001:18 |
TP2 Neg timestamp |
|
UINT32 |
RO |
0x00000000 (0dec) |
Index 6010 DRV Inputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
6010:0 |
DRV Inputs Ch.1 |
|
UINT8 |
RO |
0x15 (21dec) |
|
6010:01 |
Statusword |
Bit 0 : Ready to switch onBit 1 : Switched onBit 2 : Operation enabledBit 3 : FaultBit 4 : reservedBit 5 : reservedBit 6 : Switch on disabledBit 7 : WarningBit 8 + 9 : reservedBit 10 : TxPDOToggleBit 11 : Internal limit activeBit 12 : Drive follows the command valueBit 13 : Input cycle counterBit 14 - 15 : reserved |
UINT16 |
RO |
0x0000 (0dec) |
|
6010:03 |
Modes of operation display |
permitted values:
|
UINT8 |
RO |
0x00 (0dec) |
|
6010:06 |
Following error actual value |
|
INT32 |
RO |
0x00000000 (0dec) |
|
6010:07 |
Velocity actual value |
|
INT32 |
RO |
0x00000000 (0dec) |
|
6010:08 |
Torque actual value |
|
INT16 |
RO |
0x0000 (0dec) |
|
6010:12 |
Info data 1 |
|
UINT16 |
RO |
0x0000 (0dec) |
|
6010:13 |
Info data 2 |
|
UINT16 |
RO |
0x0000 (0dec) |
|
6010:14 |
Info data 3 |
|
UINT16 |
RO |
0x0000 (0dec) |
|
6010:15 |
Torque limitation status |
Bit 0 : Torque demand value is equal to ramp inputBit 1 : High velocity limit activeBit 2 : Low velocity limit activeBit 3 - 7 : reserved |
UINT8 |
RO |
0x00 (0dec) |
Index 6020 DI Inputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
6020:0 |
DI Inputs Ch.1 |
|
UINT8 |
RO |
0x07 (7dec) |
|
6020:01 |
Input 1 |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6020:02 |
Input 2 |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6020:05 |
Encoder A |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6020:06 |
Encoder B |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6020:07 |
Encoder C |
|
BOOLEAN |
RO |
0x00 (0dec) |
Index 6060 DMC Inputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
6060:0 |
DMC Inputs Ch.1 |
|
UINT8 |
RO |
0x3C (60dec) |
|
6060:02 |
DMC__FeedbackStatus__Latch extern valid |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:03 |
DMC__FeedbackStatus__Set counter done |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:0D |
DMC__FeedbackStatus__Status of extern latch |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:11 |
DMC__DriveStatus__Ready to enable |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:12 |
DMC__DriveStatus__Ready |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:13 |
DMC__DriveStatus__Warning |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:14 |
DMC__DriveStatus__Error |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:15 |
DMC__DriveStatus__Moving positive |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:16 |
DMC__DriveStatus__Moving negative |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:1C |
DMC__DriveStatus__Digital input 1 |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:1D |
DMC__DriveStatus__Digital input 2 |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:21 |
DMC__PositioningStatus__Busy |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:22 |
DMC__PositioningStatus__In-Target |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:23 |
DMC__PositioningStatus__Warning |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:24 |
DMC__PositioningStatus__Error |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:25 |
DMC__PositioningStatus__Calibrated |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:26 |
DMC__PositioningStatus__Accelerate |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:27 |
DMC__PositioningStatus__Decelerate |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:28 |
DMC__PositioningStatus__Ready to execute |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
6060:31 |
DMC__Set position |
|
INT64 |
RO |
|
|
6060:32 |
DMC__Set velocity |
|
INT16 |
RO |
0x0000 (0dec) |
|
6060:33 |
DMC__Actual drive time |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6060:34 |
DMC__Actual position lag |
|
INT64 |
RO |
|
|
6060:35 |
DMC__Actual velocity |
|
INT16 |
RO |
0x0000 (0dec) |
|
6060:36 |
DMC__Actual position |
|
INT64 |
RO |
|
|
6060:37 |
DMC__Error id |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
6060:38 |
DMC__Input cycle counter |
|
UINT8 |
RO |
0x00 (0dec) |
|
6060:39 |
DMC__Channel id |
|
UINT8 |
RO |
0x00 (0dec) |
|
6060:3A |
DMC__Latch value |
|
INT64 |
RO |
|
|
6060:3B |
DMC__Cyclic info data 1 |
|
INT16 |
RO |
0x0000 (0dec) |
|
6060:3C |
DMC__Cyclic info data 2 |
|
INT16 |
RO |
0x0000 (0dec) |
Index 6100 FB Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6100:0 | FB Inputs Ch.2 |
| UINT8 | RO | 0x15 (21dec)) |
6100:0E | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec)) |
6100:0F | Input cycle counter |
| BIT2 | RO | 0x00 (0dec)) |
6100:11 | Position |
| UINT32 | RO | 0x00000000 (0dec)) |
6100:15 | Secondary position |
| UINT32 | RO | 0x00000000 (0dec)) |
Index 6101 FB Touch probe inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6101:0 | FB Touch probe inputs Ch.2 |
| UINT8 | RO | 0x18 (24dec)) |
6101:01 | TP1 Enable |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:02 | TP1 Pos value stored |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:03 | TP1 Neg value stored |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:08 | TP1 Input |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:09 | TP2 Enable |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:0A | TP2 Pos value stored |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:0B | TP2 Neg value stored |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:10 | TP2 Input |
| BOOLEAN | RO | 0x00 (0dec)) |
6101:11 | TP1 Pos position |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:12 | TP1 Neg position |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:13 | TP2 Pos position |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:14 | TP2 Neg position |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:15 | TP1 Pos timestamp |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:16 | TP1 Neg timestamp |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:17 | TP2 Pos timestamp |
| UINT32 | RO | 0x00000000 (0dec)) |
6101:18 | TP2 Neg timestamp |
| UINT32 | RO | 0x00000000 (0dec)) |
Index 6110 DRV Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6110:0 | DRV Inputs Ch.2 |
| UINT8 | RO | 0x15 (21dec)) |
6110:01 | Statusword | Bit 0: Ready to switch onBit 1: Switched onBit 2: Operation enabledBit 3: FaultBit 4: reservedBit 5: reservedBit 6: Switch on disabledBit 7: WarningBit 8 + 9: reservedBit 10: TxPDOToggleBit 11: Internal limit activeBit 12: Drive follows the command valueBit 13: Input cycle counterBit 14–15: reserved | UINT16 | RO | 0x0000 (0dec)) |
6110:03 | Modes of operation display | permitted values:
| UINT8 | RO | 0x00 (0dec)) |
6110:06 | Following error actual value |
| INT32 | RO | 0x00000000 (0dec)) |
6110:07 | Velocity actual value |
| INT32 | RO | 0x00000000 (0dec)) |
6110:08 | Torque actual value |
| INT16 | RO | 0x0000 (0dec)) |
6110:12 | Info data 1 |
| UINT16 | RO | 0x0000 (0dec)) |
6110:13 | Info data 2 |
| UINT16 | RO | 0x0000 (0dec)) |
6110:14 | Info data 3 |
| UINT16 | RO | 0x0000 (0dec)) |
6110:15 | Torque limitation status | Bit 0: Torque demand value is equal to ramp inputBit 1: High velocity limit activeBit 2: Low velocity limit activeBit 3–7: reserved | UINT8 | RO | 0x00 (0dec)) |
Index 6120 DI Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6120:0 | DI Inputs Ch.2 |
| UINT8 | RO | 0x07 (7dec)) |
6120:01 | Input 1 |
| BOOLEAN | RO | 0x00 (0dec)) |
6120:02 | Input 2 |
| BOOLEAN | RO | 0x00 (0dec)) |
6120:05 | Encoder A |
| BOOLEAN | RO | 0x00 (0dec)) |
6120:06 | Encoder B |
| BOOLEAN | RO | 0x00 (0dec)) |
6120:07 | Encoder C |
| BOOLEAN | RO | 0x00 (0dec)) |
Index 6160 DMC Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6160:0 | DMC Inputs Ch.2 |
| UINT8 | RO | 0x3C (60dec)) |
6160:02 | DMC__FeedbackStatus__Latch extern valid |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:03 | DMC__FeedbackStatus__Set counter done |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:0D | DMC__FeedbackStatus__Status of extern latch |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:11 | DMC__DriveStatus__Ready to enable |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:12 | DMC__DriveStatus__Ready |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:13 | DMC__DriveStatus__Warning |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:14 | DMC__DriveStatus__Error |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:15 | DMC__DriveStatus__Moving positive |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:16 | DMC__DriveStatus__Moving negative |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:1C | DMC__DriveStatus__Digital input 1 |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:1D | DMC__DriveStatus__Digital input 2 |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:21 | DMC__PositioningStatus__Busy |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:22 | DMC__PositioningStatus__In-Target |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:23 | DMC__PositioningStatus__Warning |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:24 | DMC__PositioningStatus__Error |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:25 | DMC__PositioningStatus__Calibrated |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:26 | DMC__PositioningStatus__Accelerate |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:27 | DMC__PositioningStatus__Decelerate |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:28 | DMC__PositioningStatus__Ready to execute |
| BOOLEAN | RO | 0x00 (0dec)) |
6160:31 | DMC__Set position |
| INT64 | RO |
|
6160:32 | DMC__Set velocity |
| INT16 | RO | 0x0000 (0dec)) |
6160:33 | DMC__Actual drive time |
| UINT32 | RO | 0x00000000 (0dec)) |
6160:34 | DMC__Actual position lag |
| INT64 | RO |
|
6160:35 | DMC__Actual velocity |
| INT16 | RO | 0x0000 (0dec)) |
6160:36 | DMC__Actual position |
| INT64 | RO |
|
6160:37 | DMC__Error id |
| UINT32 | RO | 0x00000000 (0dec)) |
6160:38 | DMC__Input cycle counter |
| UINT8 | RO | 0x00 (0dec)) |
6160:39 | DMC__Channel id |
| UINT8 | RO | 0x00 (0dec)) |
6160:3A | DMC__Latch value |
| INT64 | RO |
|
6160:3B | DMC__Cyclic info data 1 |
| INT16 | RO | 0x0000 (0dec)) |
6160:3C | DMC__Cyclic info data 2 |
| INT16 | RO | 0x0000 (0dec)) |
Index 7001 FB Touch probe outputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
7001:0 |
FB Touch probe outputs Ch.1 |
|
UINT8 |
RO |
0x0E (14dec) |
|
7001:01 |
TP1 Enable |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:02 |
TP1 Continous |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:03 |
TP1 Trigger mode |
|
BIT2 |
RO |
0x00 (0dec) |
|
7001:05 |
TP1 Enable pos edge |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:06 |
TP1 Enable neg edge |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:09 |
TP2 Enable |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:0A |
TP2 Continous |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:0B |
TP2 Trigger mode |
|
BIT2 |
RO |
0x00 (0dec) |
|
7001:0D |
TP2 Enable pos edge |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7001:0E |
TP2 Enable neg edge |
|
BOOLEAN |
RO |
0x00 (0dec) |
Index 7010 DRV Outputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
7010:0 |
DRV Outputs Ch.1 |
|
UINT8 |
RO |
0x13 (19dec) |
|
7010:01 |
Controlword |
Bit 0 : Switch onBit 1 : Enable voltageBit 2 : reservedBit 3 : Enable operationBit 4 - 6 : reservedBit 7 : Fault resetBit 8 - 15 : reserved |
UINT16 |
RO |
0x0000 (0dec) |
|
7010:03 |
Modes of operation |
permitted values:
|
UINT8 |
RW |
0x08 (8dec) |
|
7010:05 |
Target position |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
7010:06 |
Target velocity |
|
INT32 |
RO |
0x00000000 (0dec) |
|
7010:09 |
Target torque |
|
INT16 |
RO |
0x0000 (0dec) |
|
7010:0A |
Torque offset |
|
INT16 |
RO |
0x0000 (0dec) |
|
7010:0B |
Torque limitation |
|
UINT16 |
RW |
0x7FFF (32767dec) |
|
7010:0E |
Commutation angle |
|
UINT16 |
RO |
0x0000 (0dec) |
|
7010:0F |
Velocity offset |
|
INT32 |
RO |
0x00000000 (0dec) |
|
7010:10 |
Positive torque limit value |
|
UINT16 |
RW |
0x7FFF (32767dec) |
|
7010:11 |
Negative torque limit value |
|
UINT16 |
RW |
0x7FFF (32767dec) |
|
7010:12 |
Low velocity limit value |
|
INT32 |
RW |
0x00000000 (0dec) |
|
7010:13 |
High velocity limit value |
|
INT32 |
RW |
0x00000000 (0dec) |
Index 7060 DMC Outputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
7060:0 |
DMC Outputs Ch.1 |
|
UINT8 |
RO |
0x36 (54dec) |
|
7060:02 |
DMC__FeedbackControl__Enable latch extern on positive edge |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:03 |
DMC__FeedbackControl__Set counter |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:04 |
DMC__FeedbackControl__Enable latch extern on negative edge |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:11 |
DMC__DriveControl__Enable |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:12 |
DMC__DriveControl__Reset |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:21 |
DMC__PositioningControl__Execute |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:22 |
DMC__PositioningControl__Emergency stop |
|
BOOLEAN |
RO |
0x00 (0dec) |
|
7060:31 |
DMC__Set counter value |
|
INT64 |
RO |
|
|
7060:32 |
DMC__Target position |
|
INT64 |
RO |
|
|
7060:33 |
DMC__Target velocity |
|
INT16 |
RO |
0x0000 (0dec) |
|
7060:34 |
DMC__Start type |
|
UINT16 |
RO |
0x0000 (0dec) |
|
7060:35 |
DMC__Target acceleration |
|
UINT16 |
RO |
0x0000 (0dec) |
|
7060:36 |
DMC__Target deceleration |
|
UINT16 |
RO |
0x0000 (0dec) |
Index 7101 FB Touch probe outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7101:0 | FB Touch probe outputs Ch.2 |
| UINT8 | RO | 0x0E (14dec)) |
7101:01 | TP1 Enable |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:02 | TP1 Continous |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:03 | TP1 Trigger mode |
| BIT2 | RO | 0x00 (0dec)) |
7101:05 | TP1 Enable pos edge |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:06 | TP1 Enable neg edge |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:09 | TP2 Enable |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:0A | TP2 Continous |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:0B | TP2 Trigger mode |
| BIT2 | RO | 0x00 (0dec)) |
7101:0D | TP2 Enable pos edge |
| BOOLEAN | RO | 0x00 (0dec)) |
7101:0E | TP2 Enable neg edge |
| BOOLEAN | RO | 0x00 (0dec)) |
Index 7110 DRV Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7110:0 | DRV Outputs Ch.2 |
| UINT8 | RO | 0x13 (19dec)) |
7110:01 | Controlword | Bit 0: Switch onBit 1: Enable voltageBit 2: reservedBit 3: Enable operationBit 4–6: reservedBit 7: Fault resetBit 8–15: reserved | UINT16 | RO | 0x0000 (0dec)) |
7110:03 | Modes of operation | permitted values:
| UINT8 | RW | 0x08 (8dec)) |
7110:05 | Target position |
| UINT32 | RO | 0x00000000 (0dec)) |
7110:06 | Target velocity |
| INT32 | RO | 0x00000000 (0dec)) |
7110:09 | Target torque |
| INT16 | RO | 0x0000 (0dec)) |
7110:0A | Torque offset |
| INT16 | RO | 0x0000 (0dec)) |
7110:0B | Torque limitation |
| UINT16 | RW | 0x7FFF (32767dec)) |
7110:0E | Commutation angle |
| UINT16 | RO | 0x0000 (0dec)) |
7110:0F | Velocity offset |
| INT32 | RO | 0x00000000 (0dec)) |
7110:10 | Positive torque limit value |
| UINT16 | RW | 0x7FFF (32767dec)) |
7110:11 | Negative torque limit value |
| UINT16 | RW | 0x7FFF (32767dec)) |
7110:12 | Low velocity limit value |
| INT32 | RW | 0x00000000 (0dec)) |
7110:13 | High velocity limit value |
| INT32 | RW | 0x00000000 (0dec)) |
Index 7160 DMC Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7160:0 | DMC Outputs Ch.2 |
| UINT8 | RO | 0x36 (54dec)) |
7160:02 | DMC__FeedbackControl__Enable latch extern on positive edge |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:03 | DMC__FeedbackControl__Set counter |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:04 | DMC__FeedbackControl__Enable latch extern on negative edge |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:11 | DMC__DriveControl__Enable |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:12 | DMC__DriveControl__Reset |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:21 | DMC__PositioningControl__Execute |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:22 | DMC__PositioningControl__Emergency stop |
| BOOLEAN | RO | 0x00 (0dec)) |
7160:31 | DMC__Set counter value |
| INT64 | RO |
|
7160:32 | DMC__Target position |
| INT64 | RO |
|
7160:33 | DMC__Target velocity |
| INT16 | RO | 0x0000 (0dec)) |
7160:34 | DMC__Start type |
| UINT16 | RO | 0x0000 (0dec)) |
7160:35 | DMC__Target acceleration |
| UINT16 | RO | 0x0000 (0dec)) |
7160:36 | DMC__Target deceleration |
| UINT16 | RO | 0x0000 (0dec)) |
Index F000 Modular Device Profile
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F000:0 |
Modular Device Profile |
General information for the Modular Device Profile |
UINT8 |
RO |
0x02 (2dec) |
|
F000:01 |
Index distance |
Index distance of the objects of the individual channels |
UINT16 |
RO |
0x0010 (16dec) |
|
F000:02 |
Maximum number of modules |
Number of channels |
UINT16 |
RO |
0x0017 (23dec) |
Index F008 Code word
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F008:0 |
Code word |
|
UINT32 |
RW |
0x00000000 (0dec) |
Index F010 Module Profile List
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F010:0 |
Module Profile List |
|
UINT8 |
RO |
0x17 (23dec) |
|
F010:01 |
SubIndex 001 |
|
UINT32 |
RO |
0x00000201 (513dec) |
|
F010:02 |
SubIndex 002 |
|
UINT32 |
RO |
0x000002E6 (742dec) |
|
F010:03 |
SubIndex 003 |
|
UINT32 |
RO |
0x00000064 (100dec) |
|
F010:04 |
SubIndex 004 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:05 |
SubIndex 005 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:06 |
SubIndex 006 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:07 |
SubIndex 007 |
|
UINT32 |
RO |
0x000002EE (750dec) |
|
F010:08 |
SubIndex 008 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:09 |
SubIndex 009 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:0A |
SubIndex 010 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:0B |
SubIndex 011 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:0C |
SubIndex 012 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:0D |
SubIndex 013 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:0E |
SubIndex 014 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:0F |
SubIndex 015 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:10 |
SubIndex 016 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:11 |
SubIndex 017 |
|
UINT32 |
RO |
0x00000201 (513dec) |
|
F010:12 |
SubIndex 018 |
|
UINT32 |
RO |
0x000002E6 (742dec) |
|
F010:13 |
SubIndex 019 |
|
UINT32 |
RO |
0x00000064 (100dec) |
|
F010:14 |
SubIndex 020 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:15 |
SubIndex 021 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:16 |
SubIndex 022 |
|
UINT32 |
RO |
0x00000000 (0dec) |
|
F010:17 |
SubIndex 023 |
|
UINT32 |
RO |
0x000002EE (750dec) |
Index F081 Download revision
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F081:0 |
Download revision |
|
UINT8 |
RO |
0x01 (1dec) |
|
F081:01 |
Revision number |
|
UINT32 |
RW |
0x00000000 (0dec) |
Index FB00 Command
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
FB00:0 |
Command |
|
UINT8 |
RO |
0x03 (3dec) |
|
FB00:01 |
Request |
|
OCTET-STRING[2] |
RW |
{0} |
|
FB00:02 |
Status |
|
UINT8 |
RO |
0x00 (0dec) |
|
FB00:03 |
Response |
|
OCTET-STRING[6] |
RO |
{0} |
Index FB13 DRV Key code
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
FB13:0 |
DRV Key code |
|
UINT8 |
RO |
0x01 (1dec) |
|
FB13:01 |
Code |
|
OCTET-STRING[32] |
RW |
{0} |
Index FB40 Memory interface
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
FB40:0 |
Memory interface |
|
UINT8 |
RO |
0x03 (3dec) |
|
FB40:01 |
Address |
|
UINT32 |
RW |
0x00000000 (0dec) |
|
FB40:02 |
Length |
|
UINT16 |
RW |
0x0000 (0dec) |
|
FB40:03 |
Data |
|
OCTET-STRING[8] |
RW |
{0} |