1A0n, 1A80, 1A81 | Mapping TxPDO
Index 1A00 IO TxPDOPDO-Map Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A00:0 | IO TxPDOPDO-Map Ch.1 | PDO Mapping TxPDO 1 | UINT8 | RW | 0x01 (1dec) |
1A00:01 | SubIndex 001 | 1st PDO Mapping entry (8 bits align) | UINT32 | RW | 0x0000:00, 8 |
Index 1A01 IO TxPDOPDO-Map Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A01:0 | IO TxPDOPDO-Map Ch.2 | PDO Mapping TxPDO 2 | UINT8 | RW | 0x01 (1dec) |
1A01:01 | SubIndex 001 | 1st PDO Mapping entry (8 bits align) | UINT32 | RW | 0x0000:00, 8 |
Index 1A02 IO TxPDOPDO-Map Ch.3
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A02:0 | IO TxPDOPDO-Map Ch.3 | PDO Mapping TxPDO 3 | UINT8 | RW | 0x01 (1dec) |
1A02:01 | SubIndex 001 | 1st PDO Mapping entry (8 bits align) | UINT32 | RW | 0x0000:00, 8 |
Index 1A03 IO TxPDOPDO-Map Ch.4
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A03:0 | IO TxPDOPDO-Map Ch.4 | PDO Mapping TxPDO 4 | UINT8 | RW | 0x01 (1dec) |
1A03:01 | SubIndex 001 | 1st PDO Mapping entry (8 bits align) | UINT32 | RW | 0x0000:00, 8 |
Index 1A80 DeviceState TxPDO-Map Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A80:0 | DeviceState TxPDO-Map Inputs | PDO Mapping TxPDO 5 | UINT8 | RW | 0x04 (4dec) |
1A80:01 | SubIndex 001 | 1st PDO Mapping entry (object 0xF100 (Diagnosis Status data), entry 0x01 (State Ch1)) | UINT32 | RW | 0xF100:01, 8 |
1A80:02 | SubIndex 002 | 2nd PDO Mapping entry (object 0xF100 (Diagnosis Status data), entry 0x02 (State Ch2)) | UINT32 | RW | 0xF100:02, 8 |
1A80:03 | SubIndex 003 | 3rd PDO Mapping entry (object 0xF100 (Diagnosis Status data), entry 0x03 (State Ch3)) | UINT32 | RW | 0xF100:03, 8 |
1A80:04 | SubIndex 004 | 4th PDO Mapping entry (object 0xF100 (Diagnosis Status data), entry 0x04 (State Ch4)) | UINT32 | RW | 0xF100:04, 8 |
Index 1A81 DeviceState TxPDO-Map Inputs Device
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A81:0 | DeviceState TxPDO-Map Inputs Device | PDO Mapping TxPDO 6 | UINT8 | RW | 0x04 (4dec) |
1A81:01 | SubIndex 001 | 1st PDO Mapping entry (12 bits align) | UINT32 | RW | 0x0000:00, 12 |
1A81:02 | SubIndex 002 | 2nd PDO Mapping entry (object 0xF101 (DeviceState Status data), entry 0x0D (Device Diag)) | UINT32 | RW | 0xF101:0D, 1 |
1A81:03 | SubIndex 003 | 3rd PDO Mapping entry (2 bits align) | UINT32 | RW | 0x0000:00, 2 |
1A81:04 | SubIndex 004 | 5th PDO Mapping entry (object 0xF101 (DeviceState Status data), entry 0x0D (Device State)) | UINT32 | RW | 0xF101:10, 1 |