14nn | Exclude RxPDO

Index ENC 1400 RxPDO-Par Control Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1400:0

ENC RxPDO-Par Control Ch.1

PDO Parameter RxPDO 1

UINT8

RO

0x06 (6dec)

1400:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 1.

OCTET-STRING[22]

RO

01 16 02 16 03 16 04 16 05 16 06 16 07 16 0A 16 0B 16 0C 16 0D 16

Index 1401 ENC RxPDO-Par Control Compact Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1401:0

ENC RxPDO-Par Control Compact Ch.1

PDO Parameter RxPDO 2

UINT8

RO

0x06 (6dec)

1401:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 2.

OCTET-STRING[22]

RO

00 16 02 16 03 16 04 16 05 16 06 16 07 16 00 00 00 00 00 00 00 00

Index 1402 ENC RxPDO-Par Control Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1402:0

ENC RxPDO-Par Control Ch.1

PDO Parameter RxPDO 3

UINT8

RO

0x06 (6dec)

1402:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 3.

OCTET-STRING[22]

RO

00 16 01 16 03 16 04 16 05 16 06 16 07 16 00 00 00 00 00 00 00 00

Index 1403 ENC RxPDO-Par Control Compact Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1403:0

ENC RxPDO-Par Control Compact Ch.1

PDO Parameter RxPDO 4

UINT8

RO

0x06 (6dec)

1403:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 4.

OCTET-STRING[22]

RO

00 16 01 16 02 16 04 16 05 16 06 16 07 16 00 00 00 00 00 00 00 00

Index 1404 ENC RxPDO-Par Control Counter Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1404:0

ENC RxPDO-Par Control Counter Ch.1

PDO Parameter RxPDO 5

UINT8

RO

0x06 (6dec)

1404:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 5.

OCTET-STRING[22]

RO

00 16 01 16 02 16 03 16 05 16 06 16 07 16 00 00 00 00 00 00 00 00

Index 1405 ENC RxPDO-Par Control Compact Counter Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1405:0

ENC RxPDO-Par Control Compact Counter Ch.1

PDO Parameter RxPDO 6

UINT8

RO

0x06 (6dec)

1405:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 6.

OCTET-STRING[22]

RO

00 16 01 16 02 16 03 16 04 16 06 16 07 16 00 00 00 00 00 00 00 00

Index 1406 ENC RxPDO-Par Control Legacy Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1406:0

ENC RxPDO-Par Control Legacy Ch.1

PDO Parameter RxPDO 7

UINT8

RO

0x06 (6dec)

1406:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 7.

OCTET-STRING[22]

RO

00 16 01 16 02 16 03 16 04 16 05 16 07 16 00 00 00 00 00 00 00 00

Index 1407 ENC RxPDO-Par Control Compact Legacy Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1407:0

ENC RxPDO-Par Control Compact Legacy Ch.1

PDO Parameter RxPDO 8

UINT8

RO

0x06 (6dec)

1407:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 8.

OCTET-STRING[22]

RO

00 16 01 16 02 16 03 16 04 16 05 16 06 16 00 00 00 00 00 00 00 00

Index 140A ENC RxPDO-Par Control Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

140A:0

ENC RxPDO-Par Control Ch.2

PDO Parameter RxPDO 9

UINT8

RO

0x06 (6dec)

140A:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 9.

OCTET-STRING[22]

RO

00 16
01 16 06 16 07 16 0B 16 0C 16 00 00 00 00 00 00 00 00

Index 140B ENC RxPDO-Par Control Compact Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

140B:0

ENC RxPDO-Par Control Compact Ch.2

PDO Parameter RxPDO 10

UINT8

RO

0x06 (6dec)

140B:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 10.

OCTET-STRING[22]

RO

00 16
01 16 06 16 07 16 0A 16 0C 16 0D 16 00 00 00 00 00 00 00 00

Index 140C ENC RxPDO-Par Control Counter Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

140C:0

ENC RxPDO-Par Control Counter Ch.2

PDO Parameter RxPDO 11

UINT8

RO

0x06 (6dec)

140C:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 11.

OCTET-STRING[22]

RO

00 16
01 16 06 16 07 16 0A 16 0B 16 0D 16 00 00 00 00 00 00 00 00

Index 140D ENC RxPDO-Par Control Compact Counter Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

140D:0

ENC RxPDO-Par Control Compact Counter Ch.2

PDO Parameter RxPDO 12

UINT8

RO

0x06 (6dec)

140D:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 12.

OCTET-STRING[22]

RO

00 16
01 16 06 16 07 16 0A 16 0B 16 0C 16 00 00 00 00 00 00 00 00