Standard objects
Index 1000 Device type
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1000:0 | Device type | Device type of the EtherCAT slave: the low word contains the used CoE profile (5001). The high word contains the module profile according to the modular device profile. | UINT32 | RO | 0x01901389 (26219401dec) |
Index 1008 Device name
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1008:0 | Device name | Device name of the EtherCAT slave | STRING | RO | EL407x |
Index 1009 Hardware version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1009:0 | Hardware version | Hardware version of the EtherCAT slave | STRING | RO | – |
Index 100A Software version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100A:0 | Software version | Firmware version of the EtherCAT slave | STRING | RO | 00 |
Index 100B Bootloader version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100B:0 | Bootloader version | Bootloader version | STRING | RO | n/a |
Index 1018 Identity
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1018:0 | Identity | Information for identifying the slave | UINT8 | RO | 0x04 (4dec) |
1018:01 | Vendor ID | Vendor ID for the EtherCAT slave | UINT32 | RO | 0x00000002 (2dec) |
1018:02 | Product code | Product code of the EtherCAT slave | UINT32 | RO | 0x0FEE3052 (267268178dec) |
1018:03 | Revision | Revision number of the EtherCAT slave; the low word (bit 0–15) indicates the special terminal number, the high word (bit 16–31) refers to the device description | UINT32 | RO | 0x00000000 (0dec) |
1018:04 | Serial number | Serial number of the EtherCAT slave; the low byte (bit 0–7) of the low word contains the year of production, the high byte (bit 8–15) of the low word contains the week of production, the high word (bit 16–31) is 0 | UINT32 | RO | 0x00000000 (0dec) |
Index 10E2 Manufacturer-specific Identification Code*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10E2:0 | Manufacturer-specific Identification Code | Manufacturer-specific Identification Code | UINT8 | RO | 0x01 (1dec) |
10E2:01 | SubIndex 001 | reserved | STRING | RO |
|
Index 10F0 Backup parameter handling
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F0:0 | Backup parameter handling | Information for standardized loading and saving of backup entries | UINT8 | RO | 0x01 (1dec) |
10F0:01 | Checksum | Checksum across all backup entries of the EtherCAT slave | UINT32 | RO | 0x00000000 (0dec) |
Index 10F3 Diagnosis History
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F3:0 | Diagnosis History | Maximum subindex | UINT8 | RO | 0x15 (21dec) |
10F3:01 | Maximum Messages | Maximum number of stored messages | UINT8 | RO | 0x00 (0dec) |
10F3:02 | Newest Message | Subindex of the latest message | UINT8 | RO | 0x00 (0dec) |
10F3:03 | Newest Acknowledged Message | Subindex of the last acknowledged message | UINT8 | RW | 0x00 (0dec) |
10F3:04 | New Messages Available | Indicates that a new message is available. | BOOLEAN | RO | 0x00 (0dec) |
10F3:05 | Flags | not used | UINT16 | RW | 0x0000 (0dec) |
10F3:06 | Diagnosis Message 001 | Message 1 | OCTET STRING[24] | RO | {0} |
… | … | …. | … | … | … |
10F3:15 | Diagnosis Message 016 | Message 16 | OCTET STRING[24] | RO | {0} |
Index 10F8 Timestamp Object
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F8:0 | Timestamp Object | Timestamp Object [ns] For SM synchronous operation: Time since power-on For DC synchronous operation: copy of the DC time Time can be used by the device e.g. for timestamps of the DiagMessage | UINT64 | RO |
|
Index 1420 AO RxPDO Par Standard (INT16) Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1420:0 | AO RxPDO Par Standard (INT16) | PDO Parameter RxPDO 33 | UINT8 | RO | 0x06 (6dec) |
1420:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 33 | OCTET STRING[2] | RO | 22 16 |
Index 1422 AO RxPDO Par Standard (Real32) Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1422:0 | AO RxPDO Par Standard (Real32) Ch. 1 | PDO Parameter RxPDO 35 | UINT8 | RO | 0x06 (6dec) |
1422:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 35 | OCTET STRING[2] | RO | 20 16 |
Index 1444 AO RxPDO Par Standard (INT16) Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1444:0 | AO RxPDO Par Standard (INT16) Ch.2 | PDO Parameter RxPDO 69 | UINT8 | RO | 0x06 (6dec) |
1444:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 69 | OCTET STRING[2] | RO | 46 16 |
Index 1446 AO RxPDO Par Standard (Real32) Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1446:0 | AO RxPDO Par Standard (Real32) Ch.2 | PDO Parameter RxPDO 71 | UINT8 | RO | 0x06 (6dec) |
1446:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 71 | OCTET STRING[2] | RO | 44 16 |
Index 1468 AO RxPDO Par Standard (INT16) Ch.3*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1468:0 | AO RxPDO Par Standard (INT16) Ch.3 | PDO Parameter RxPDO 105 | UINT8 | RO | 0x06 (6dec) |
1468:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 105 | OCTET STRING[2] | RO | 6A 16 |
*) EL4074, EL4078 only
Index 146A AO RxPDO Par Standard (Real32) Ch.3*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
146A:0 | AO RxPDO Par Standard (Real32) Ch.3 | PDO Parameter RxPDO 107 | UINT8 | RO | 0x06 (6dec) |
146A:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 107 | OCTET STRING[2] | RO | 68 16 |
*) EL4074, EL4078 only
Index 148C AO RxPDO Par Standard (INT16) Ch.4*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
148C:0 | AO RxPDO Par Standard (INT16) Ch.4 | PDO Parameter RxPDO 141 | UINT8 | RO | 0x06 (6dec) |
148C:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 141 | OCTET STRING[2] | RO | 8E 16 |
*) EL4074, EL4078 only
Index 148E AO RxPDO Par Standard (Real32) Ch.4*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
148E:0 | AO RxPDO Par Standard (Real32) Ch.4 | PDO Parameter RxPDO 143 | UINT8 | RO | 0x06 (6dec) |
148E:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 143 | OCTET STRING[2] | RO | 8C 16 |
*) EL4074, EL4078 only
Index 14B0 AO RxPDO Par Standard (INT16) Ch.5*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
14B0:0 | AO RxPDO Par Standard (INT16) Ch.5 | PDO Parameter RxPDO 177 | UINT8 | RO | 0x06 (6dec) |
14B00:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 177 | OCTET STRING[2] | RO | B2 16 |
*) EL4078 only
Index 14B2 AO RxPDO Par Standard (Real32) Ch.5*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
14B2:0 | AO RxPDO Par Standard (Real32) Ch.5 | PDO Parameter RxPDO 179 | UINT8 | RO | 0x06 (6dec) |
14B2:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 179 | OCTET STRING[2] | RO | B0 16 |
*) EL4078 only
Index 14D4 AO RxPDO Par Standard (INT16) Ch.6*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
14D4:0 | AO RxPDO Par Standard (INT16) Ch.6 | PDO Parameter RxPDO 213 | UINT8 | RO | 0x06 (6dec) |
14D4:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 213 | OCTET STRING[2] | RO | D6 16 |
*) EL4078 only
Index 14D6 AO RxPDO Par Standard (Real32) Ch.6*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
14D6:0 | AO RxPDO Par Standard (Real32) Ch.6 | PDO Parameter RxPDO 215 | UINT8 | RO | 0x06 (6dec) |
14D6:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 215 | OCTET STRING[2] | RO | D4 16 |
*) EL4078 only
Index 14F8 AO RxPDO Par Standard (INT16) Ch.7*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
14F8:0 | AO RxPDO Par Standard (INT16) Ch.7 | PDO Parameter RxPDO 249 | UINT8 | RO | 0x06 (6dec) |
14F8:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 249 | OCTET STRING[2] | RO | FA 16 |
*) EL4078 only
Index 14FA AO RxPDO Par Standard (Real32) Ch.7*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
14FA:0 | AO RxPDO Par Standard (Real32) Ch.7 | PDO Parameter RxPDO 251 | UINT8 | RO | 0x06 (6dec) |
14FA:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 251 | OCTET STRING[2] | RO | F8 16 |
*) EL4078 only
Index 151C AO RxPDO Par Standard (INT16) Ch.8*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
151C:0 | AO RxPDO Par Standard (INT16) Ch.8 | PDO Parameter RxPDO 285 | UINT8 | RO | 0x06 (6dec) |
151C:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 285 | OCTET STRING[2] | RO | 1E 17 |
*) EL4078 only
Index 151E AO RxPDO Par Standard (Real32) Ch.8*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
151E:0 | AO RxPDO Par Standard (Real32) Ch.8 | PDO Parameter RxPDO 287 | UINT8 | RO | 0x06 (6dec) |
151E:06 | Exclude RxPDOs | Specifies the RxPDOs (index of RxPDO mapping objects) that may not be transferred together with RxPDO 287 | OCTET STRING[2] | RO | 1C 17 |
*) EL4078 only
Index 1620 AO RxPDO Map Standard (INT16) Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1620:0 | AO RxPDO Map Standard (INT16) Ch.1 | PDO Mapping RxPDO 33 | UINT8 | RO | 0x01 (1dec) |
1620:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7000 (AO Outputs Ch.1), entry 0x11 (Value)) | UINT32 | RO | 0x7000:11, 16 |
Index 1622 AO RxPDO Map Standard (Real32) Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1622:0 | AO RxPDO Map Standard (Real32) Ch.1 | PDO Mapping RxPDO 35 | UINT8 | RO | 0x01 (1dec) |
1622:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7000 (AO Outputs Ch.1), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7000:13, 32 |
Index 1623 AO RxPDO Map Cycle Counter Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1623:0 | AO RxPDO Map Cycle Counter Ch.1 | PDO Mapping RxPDO 36 | UINT8 | RO | 0x01 (1dec) |
1623:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7000 (AO Outputs Ch.1), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7000:14, 16 |
Index 1644 AO RxPDO Map Standard (INT16) Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1644:0 | AO RxPDO Map Standard (INT16) Ch.2 | PDO Mapping RxPDO 69 | UINT8 | RO | 0x01 (1dec) |
1644:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7010 (AO Outputs Ch.2), entry 0x11 (Value)) | UINT32 | RO | 0x7010:11, 16 |
Index 1646 AO RxPDO Map Standard (Real32) Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1646:0 | AO RxPDO Map Standard (Real32) Ch.2 | PDO Mapping RxPDO 71 | UINT8 | RO | 0x01 (1dec) |
1646:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7010 (AO Outputs Ch.2), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7010:13, 32 |
Index 1647 AO RxPDO Map Cycle Counter Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1647:0 | AO RxPDO Map Cycle Counter Ch.2 | PDO Mapping RxPDO 72 | UINT8 | RO | 0x01 (1dec) |
1647:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7010 (AO Outputs Ch.2), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7010:14, 16 |
Index 1668 AO RxPDO Map Standard (INT16) Ch.3*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1668:0 | AO RxPDO Map Standard (INT16) Ch.3 | PDO Mapping RxPDO 105 | UINT8 | RO | 0x01 (1dec) |
1668:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7020 (AO Outputs Ch.3), entry 0x11 (Value)) | UINT32 | RO | 0x7020:11, 16 |
*) EL4074, EL4078 only
Index 166A AO RxPDO Map Standard (Real32) Ch.3*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
166A:0 | AO RxPDO Map Standard (Real32) Ch.3 | PDO Mapping RxPDO 107 | UINT8 | RO | 0x01 (1dec) |
166A:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7020 (AO Outputs Ch.3), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7020:13, 32 |
*) EL4074, EL4078 only
Index 166B AO RxPDO Map Cycle Counter Ch.3*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
166B:0 | AO RxPDO Map Cycle Counter Ch.3 | PDO Mapping RxPDO 108 | UINT8 | RO | 0x01 (1dec) |
166B:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7020 (AO Outputs Ch.3), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7020:14, 16 |
*) EL4074, EL4078 only
Index 168C AO RxPDO Map Standard (INT16) Ch.4*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
168C:0 | AO RxPDO Map Standard (INT16) Ch.4 | PDO Mapping RxPDO 141 | UINT8 | RO | 0x01 (1dec) |
168C:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7030 (AO Outputs Ch.4), entry 0x11 (Value)) | UINT32 | RO | 0x7030:11, 16 |
*) EL4074, EL4078 only
Index 168E AO RxPDO Map Standard (Real32) Ch.4*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
168E:0 | AO RxPDO Map Standard (Real32) Ch.4 | PDO Mapping RxPDO 143 | UINT8 | RO | 0x01 (1dec) |
168E:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7030 (AO Outputs Ch.4), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7030:13, 32 |
*) EL4074, EL4078 only
Index 168F AO RxPDO Map Cycle Counter Ch.4*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
168F:0 | AO RxPDO Map Cycle Counter Ch.4 | PDO Mapping RxPDO 144 | UINT8 | RO | 0x01 (1dec) |
168F:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7030 (AO Outputs Ch.4), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7030:14, 16 |
*) EL4074, EL4078 only
Index 16B0 AO RxPDO Map Standard (INT16) Ch.5*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16B0:0 | AO RxPDO Map Standard (INT16) Ch.5 | PDO Mapping RxPDO 177 | UINT8 | RO | 0x01 (1dec) |
16B0:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7040 (AO Outputs Ch.5), entry 0x11 (Value)) | UINT32 | RO | 0x7040:11, 16 |
*) EL4078 only
Index 16B2 AO RxPDO Map Standard (Real32) Ch.5*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16B2:0 | AO RxPDO Map Standard (Real32) Ch.5 | PDO Mapping RxPDO 179 | UINT8 | RO | 0x01 (1dec) |
16B2:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7040 (AO Outputs Ch.5), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7040:13, 32 |
*) EL4078 only
Index 16B3 AO RxPDO Map Cycle Counter Ch.5*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16B3:0 | AO RxPDO Map Cycle Counter Ch.5 | PDO Mapping RxPDO 180 | UINT8 | RO | 0x01 (1dec) |
16B3:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7040 (AO Outputs Ch.5), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7040:14, 16 |
*) EL4078 only
Index 16D4 AO RxPDO Map Standard (INT16) Ch.6*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16D4:0 | AO RxPDO Map Standard (INT16) Ch.6 | PDO Mapping RxPDO 213 | UINT8 | RO | 0x01 (1dec) |
16D4:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7050 (AO Outputs Ch.6), entry 0x11 (Value)) | UINT32 | RO | 0x7050:11, 16 |
*) EL4078 only
Index 16D6 AO RxPDO Map Standard (Real32) Ch.6*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16D6:0 | AO RxPDO Map Standard (Real32) Ch.6 | PDO Mapping RxPDO 215 | UINT8 | RO | 0x01 (1dec) |
16D6:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7050 (AO Outputs Ch.6), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7050:13, 32 |
*) EL4078 only
Index 16D7 AO RxPDO Map Cycle Counter Ch.6*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16D7:0 | AO RxPDO Map Cycle Counter Ch.6 | PDO Mapping RxPDO 216 | UINT8 | RO | 0x01 (1dec) |
16D7:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7050 (AO Outputs Ch.6), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7050:14, 16 |
*) EL4078 only
Index 16F8 AO RxPDO Map Standard (INT16) Ch.7*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16F8:0 | AO RxPDO Map Standard (INT16) Ch.7 | PDO Mapping RxPDO 249 | UINT8 | RO | 0x01 (1dec) |
16F8:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7060 (AO Outputs Ch.7), entry 0x11 (Value)) | UINT32 | RO | 0x7060:11, 16 |
*) EL4078 only
Index 16FA AO RxPDO Map Standard (Real32) Ch.7*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16FA:0 | AO RxPDO Map Standard (Real32) Ch.7 | PDO Mapping RxPDO 251 | UINT8 | RO | 0x01 (1dec) |
16FA:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7060 (AO Outputs Ch.7), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7060:13, 32 |
*) EL4078 only
Index 16FB AO RxPDO Map Cycle Counter Ch.7*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
16FB:0 | AO RxPDO Map Cycle Counter Ch.7 | PDO Mapping RxPDO 252 | UINT8 | RO | 0x01 (1dec) |
16FB:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7060 (AO Outputs Ch.7), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7060:14, 16 |
*) EL4078 only
Index 171C AO RxPDO Map Standard (INT16) Ch.8*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
171C:0 | AO RxPDO Map Standard (INT16) Ch.8 | PDO Mapping RxPDO 285 | UINT8 | RO | 0x01 (1dec) |
171C:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7070 (AO Outputs Ch.8), entry 0x11 (Value)) | UINT32 | RO | 0x7070:11, 16 |
*) EL4078 only
Index 171E AO RxPDO Map Standard (Real32) Ch.8*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
171E:0 | AO RxPDO Map Standard (Real32) Ch.8 | PDO Mapping RxPDO 287 | UINT8 | RO | 0x01 (1dec) |
171E:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7070 (AO Outputs Ch.8), entry 0x13 (Value (Real32))) | UINT32 | RO | 0x7070:13, 32 |
*) EL4078 only
Index 171F AO RxPDO Map Cycle Counter Ch.8*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
171F:0 | AO RxPDO Map Cycle Counter Ch.8 | PDO Mapping RxPDO 288 | UINT8 | RO | 0x01 (1dec) |
171F:01 | SubIndex 001 | PDO Mapping entry no. 1 (object 0x7070 (AO Outputs Ch.8), entry 0x14 (Output Cycle Counter)) | UINT32 | RO | 0x7070:14, 16 |
*) EL4078 only
Index 1A20 AO TxPDO Map Status Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A20:0 | AO TxPDO Map Status Ch.1 | PDO Mapping TxPDO 33 | UINT8 | RO | 0x08 (8dec) |
1A20:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A20:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6000 (AO Inputs Ch.1), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6000:02, 1 |
1A20:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6000 (AO Inputs Ch.1), entry 0x03 (Underrange)) | UINT32 | RO | 0x6000:03, 1 |
1A20:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6000 (AO Inputs Ch.1), entry 0x04 (Overrange)) | UINT32 | RO | 0x6000:04, 1 |
1A20:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A20:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6000 (AO Inputs Ch.1), entry 0x06 (Warning)) | UINT32 | RO | 0x6000:06, 1 |
1A20:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6000 (AO Inputs Ch.1), entry 0x07 (Error)) | UINT32 | RO | 0x6000:07, 1 |
1A20:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
Index 1A41 AO TxPDO Map Status Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A41:0 | AO TxPDO Map Status Ch.2 | PDO Mapping TxPDO 66 | UINT8 | RO | 0x08 (8dec) |
1A41:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A41:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6010 (AO Inputs Ch.2), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6010:02, 1 |
1A41:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6010 (AO Inputs Ch.2), entry 0x03 (Underrange)) | UINT32 | RO | 0x6010:03, 1 |
1A41:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6010 (AO Inputs Ch.2), entry 0x04 (Overrange)) | UINT32 | RO | 0x6010:04, 1 |
1A41:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A41:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6010 (AO Inputs Ch.2), entry 0x06 (Warning)) | UINT32 | RO | 0x6010:06, 1 |
1A41:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6010 (AO Inputs Ch.2), entry 0x07 (Error)) | UINT32 | RO | 0x6010:07, 1 |
1A41:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
Index 1A62 AO TxPDO Map Status Ch.3*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A62:0 | AO TxPDO Map Status Ch.3 | PDO Mapping TxPDO 99 | UINT8 | RO | 0x08 (8dec) |
1A62:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A62:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6020 (AO Inputs Ch.3), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6020:02, 1 |
1A62:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6020 (AO Inputs Ch.3), entry 0x03 (Underrange)) | UINT32 | RO | 0x6020:03, 1 |
1A62:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6020 (AO Inputs Ch.3), entry 0x04 (Overrange)) | UINT32 | RO | 0x6020:04, 1 |
1A62:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A62:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6020 (AO Inputs Ch.3), entry 0x06 (Warning)) | UINT32 | RO | 0x6020:06, 1 |
1A62:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6020 (AO Inputs Ch.3), entry 0x07 (Error)) | UINT32 | RO | 0x6020:07, 1 |
1A62:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
*) EL4074, EL4078 only
Index 1A83 AO TxPDO Map Status Ch.4*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A83:0 | AO TxPDO Map Status Ch.4 | PDO Mapping TxPDO 132 | UINT8 | RO | 0x08 (8dec) |
1A83:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A83:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6030 (AO Inputs Ch.4), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6030:02, 1 |
1A83:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6030 (AO Inputs Ch.4), entry 0x03 (Underrange)) | UINT32 | RO | 0x6030:03, 1 |
1A83:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6030 (AO Inputs Ch.4), entry 0x04 (Overrange)) | UINT32 | RO | 0x6030:04, 1 |
1A83:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1A83:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6030 (AO Inputs Ch.4), entry 0x06 (Warning)) | UINT32 | RO | 0x6030:06, 1 |
1A83:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6030 (AO Inputs Ch.4), entry 0x07 (Error)) | UINT32 | RO | 0x6030:07, 1 |
1A83:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
*) EL4074, EL4078 only
Index 1AA4 AO TxPDO Map Status Ch.5*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1AA4:0 | AO TxPDO Map Status Ch.5 | PDO Mapping TxPDO 165 | UINT8 | RO | 0x08 (8dec) |
1AA4:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1AA4:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6040 (AO Inputs Ch.5), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6040:02, 1 |
1AA4:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6040 (AO Inputs Ch.5), entry 0x03 (Underrange)) | UINT32 | RO | 0x6040:03, 1 |
1AA4:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6040 (AO Inputs Ch.5), entry 0x04 (Overrange)) | UINT32 | RO | 0x6040:04, 1 |
1AA4:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1AA4:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6040 (AO Inputs Ch.5), entry 0x06 (Warning)) | UINT32 | RO | 0x6040:06, 1 |
1AA4:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6040 (AO Inputs Ch.5), entry 0x07 (Error)) | UINT32 | RO | 0x6040:07, 1 |
1AA4:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
*) EL4078 only
Index 1AC5 AO TxPDO Map Status Ch.6*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1AC5:0 | AO TxPDO Map Status Ch.6 | PDO Mapping TxPDO 198 | UINT8 | RO | 0x08 (8dec) |
1AC5:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1AC5:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6050 (AO Inputs Ch.6), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6050:02, 1 |
1AC5:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6050 (AO Inputs Ch.6), entry 0x03 (Underrange)) | UINT32 | RO | 0x6050:03, 1 |
1AC5:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6050 (AO Inputs Ch.6), entry 0x04 (Overrange)) | UINT32 | RO | 0x6050:04, 1 |
1AC5:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1AC5:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6050 (AO Inputs Ch.6), entry 0x06 (Warning)) | UINT32 | RO | 0x6050:06, 1 |
1AC5:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6050 (AO Inputs Ch.6), entry 0x07 (Error)) | UINT32 | RO | 0x6050:07, 1 |
1AC5:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
*) EL4078 only
Index 1AE6 AO TxPDO Map Status Ch.7*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1AE6:0 | AO TxPDO Map Status Ch.7 | PDO Mapping TxPDO 231 | UINT8 | RO | 0x08 (8dec) |
1AE6:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1AE6:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6060 (AO Inputs Ch.7), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6060:02, 1 |
1AE6:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6060 (AO Inputs Ch.7), entry 0x03 (Underrange)) | UINT32 | RO | 0x6060:03, 1 |
1AE6:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6060 (AO Inputs Ch.7), entry 0x04 (Overrange)) | UINT32 | RO | 0x6060:04, 1 |
1AE6:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1AE6:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6060 (AO Inputs Ch.9), entry 0x06 (Warning)) | UINT32 | RO | 0x6060:06, 1 |
1AE6:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6060 (AO Inputs Ch.7), entry 0x07 (Error)) | UINT32 | RO | 0x6060:07, 1 |
1AE6:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
*) EL4078 only
Index 1B07 AO TxPDO Map Status Ch.8*)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1B07:0 | AO TxPDO Map Status Ch.8 | PDO Mapping TxPDO 264 | UINT8 | RO | 0x08 (8dec) |
1B07:01 | SubIndex 001 | PDO Mapping entry no. 1 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1B07:02 | SubIndex 002 | PDO Mapping entry no. 2 (object 0x6070 (AO Inputs Ch.8), entry 0x02 (Output Overload)) | UINT32 | RO | 0x6070:02, 1 |
1B07:03 | SubIndex 003 | PDO Mapping entry no. 3 (object 0x6070 (AO Inputs Ch.8), entry 0x03 (Underrange)) | UINT32 | RO | 0x6070:03, 1 |
1B07:04 | SubIndex 004 | PDO Mapping entry no. 4 (object 0x6070 (AO Inputs Ch.8), entry 0x04 (Overrange)) | UINT32 | RO | 0x6070:04, 1 |
1B07:05 | SubIndex 005 | PDO Mapping entry no. 5 (1 bits align) | UINT32 | RO | 0x0000:00, 1 |
1B07:06 | SubIndex 006 | PDO Mapping entry no. 6 (object 0x6070 (AO Inputs Ch.8), entry 0x06 (Warning)) | UINT32 | RO | 0x6070:06, 1 |
1B07:07 | SubIndex 007 | PDO Mapping entry no. 7 (object 0x6070 (AO Inputs Ch.8), entry 0x07 (Error)) | UINT32 | RO | 0x6070:07, 1 |
1B07:08 | SubIndex 008 | PDO Mapping entry no. 8 (9 bits align) | UINT32 | RO | 0x0000:00, 9 |
*) EL4078 only
Index 1C00 Sync manager type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C00:0 |
Sync manager type |
Using the Sync Managers |
UINT8 |
RO |
0x04 (4dec) |
|
1C00:01 |
SubIndex 001 |
Sync Manager Type Channel 1: Mailbox Write |
UINT8 |
RO |
0x01 (1dec) |
|
1C00:02 |
SubIndex 002 |
Sync Manager Type Channel 2: Mailbox Read |
UINT8 |
RO |
0x02 (2dec) |
|
1C00:03 |
SubIndex 003 |
Sync Manager Type Channel 3: Process Data Write (Outputs) |
UINT8 |
RO |
0x03 (3dec) |
|
1C00:04 |
SubIndex 004 |
Sync Manager Type Channel 4: Process Data Read (Inputs) |
UINT8 |
RO |
0x04 (4dec) |
Index 1C12 RxPDO assign
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C12:0 | RxPDO assign | PDO Assign Outputs | UINT8 | RW | 0x08 (8dec) |
1C12:01 | Subindex 001 | Assigned RxPDO no. 1 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1622 (5666dec) |
1C12:02 | Subindex 002 | Assigned RxPDO no. 2 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1646 (5702dec) |
1C12:03 | Subindex 003 | Assigned RxPDO no. 3 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x166A (5738dec) |
1C12:04 | Subindex 004 | Assigned RxPDO no. 4 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x168E (5774dec) |
1C12:05 | Subindex 005 | Assigned RxPDO no. 5 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x16B2 (5810dec) |
1C12:06 | Subindex 006 | Assigned RxPDO no. 6 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x16D6 (5846dec) |
1C12:07 | Subindex 007 | Assigned RxPDO no. 7 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x16FA (5882dec) |
1C12:08 | Subindex 008 | Assigned RxPDO no. 8 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x171E (5918dec) |
1C12:09 | Subindex 009 | Assigned RxPDO no. 9 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0A | Subindex 010 | Assigned RxPDO no. 10 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0B | Subindex 011 | Assigned RxPDO no. 11 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0C | Subindex 012 | Assigned RxPDO no. 12 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0D | Subindex 013 | Assigned RxPDO no. 13 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0E | Subindex 014 | Assigned RxPDO no. 14 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0F | Subindex 015 | Assigned RxPDO no. 15 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:10 | Subindex 016 | Assigned RxPDO no. 16 (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
Index 1C13 TxPDO assign
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C13:0 | TxPDO assign | PDO Assign Inputs | UINT8 | RW | 0x08 (8dec) |
1C13:01 | Subindex 001 | Assigned TxPDO no. 1 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A20 (6688dec) |
1C13:02 | Subindex 002 | Assigned TxPDO no. 2 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A41 (6721dec) |
1C13:03 | Subindex 003 | Assigned TxPDO no. 3 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A62 (6754dec) |
1C13:04 | Subindex 004 | Assigned TxPDO no. 4 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A83 (6787dec) |
1C13:05 | Subindex 005 | Assigned TxPDO no. 5 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1AA4 (6820dec) |
1C13:06 | Subindex 006 | Assigned TxPDO no. 6 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1AC5 (6853dec) |
1C13:07 | Subindex 007 | Assigned TxPDO no. 7 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1AE6 (6886dec) |
1C13:08 | Subindex 008 | Assigned TxPDO no. 8 (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1B07 (6919dec) |
Index 1C32 SM output parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C32:0 | SM output parameter | Synchronization parameter for the outputs | UINT8 | RO | 0x20 (32dec) |
1C32:01 | Sync mode | Current synchronization mode:
| UINT16 | RW | 0x0001 (1dec) |
1C32:02 | Cycle time | Cycle time (in ns):
| UINT32 | RW | 0x000F4240 (1000000dec) |
1C32:03 | Shift time | Time between SYNC0 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:04 | Sync modes supported | Supported synchronization modes:
| UINT16 | RO | 0x0002 (2dec) |
1C32:05 | Minimum cycle time | Minimum cycle time (in ns) | UINT32 | RO | 0x000F4240 (1000000dec) |
1C32:06 | Calc and copy time | Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:09 | Maximum delay time | Time between SYNC1 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:0B | SM event missed counter | Number of missed SM events in OPERATIONAL (DC Mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:0C | Cycle exceeded counter | Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early) | UINT16 | RO | 0x0000 (0dec) |
1C32:0D | Shift too short counter | Number of intervals between SYNC0 and SYNC1 events that are too short (DC Mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:20 | Sync error | The synchronization was not correct in the last cycle (outputs were output too late; DC Mode only) | BOOLEAN | RO | 0x00 (0dec) |
Index 1C33 SM input parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C33:0 | SM input parameter | Synchronization parameter for the inputs | UINT8 | RO | 0x20 (32dec) |
1C33:01 | Sync mode | Current synchronization mode:
| UINT16 | RW | 0x0022 (34dec) |
1C33:02 | Cycle time |
| UINT32 | RW | 0x000F4240 (1000000dec) |
1C33:03 | Shift time | Time between SYNC0 event and reading of the inputs (in ns, DC Mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C33:04 | Sync modes supported | Supported synchronization modes:
| UINT16 | RO | 0x0002 (2dec) |
1C33:05 | Minimum cycle time | as 1C32:05 | UINT32 | RO | 0x000F4240 (1000000dec) |
1C33:06 | Calc and copy time | Time between reading of the inputs and the inputs being made available for the master (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C33:07 | Minimum delay time |
| UINT32 | RO | 0x00000000 (0dec) |
1C33:09 | Maximum delay time | Time between SYNC1 event and reading of the inputs (in ns, DC Mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C33:0B | SM event missed counter | as 1C32:11 | UINT16 | RO | 0x0000 (0dec) |
1C33:0C | Cycle exceeded counter | as 1C32:12 | UINT16 | RO | 0x0000 (0dec) |
1C33:0D | Shift too short counter | as 1C32:13 | UINT16 | RO | 0x0000 (0dec) |
1C33:20 | Sync error | as 1C32:32 | BOOLEAN | RO | 0x00 (0dec) |
Index F008 code word
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F008:0 | Code word | Code word (currently reserved) | UINT32 | RW | 0x00000000 (0dec) |
Index F009 Password protection
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F009:0 | Password protection | Password protection user calibration | UINT32 | RW | 0x00000000 (0dec) |
Index F081 Download revision
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F081:0 | Download revision | Max. subindex | UINT8 | RO | 0x01 (1dec) |
F081:01 | Download revision | The subindex 0xF081:01 (Download revision) describes the revision level of the module. | UINT32 | RW | 0x00000000 (0dec) |