0x1A20–0x1A2E | Mapping AI TxPDO Cycle Counter
Index 1A20 AI TxPDO-Map Cycle Counter Ch. 1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A20:0 | AI TxPDO-Map Cycle Counter Ch.1 | PDO Mapping TxPDO 33 | UINT8 | RO | 0x01 (1dec) |
1A20:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6000 (AI Inputs Ch. 1), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6000:14, 16 |
Index 1A22 AI TxPDO-Map Cycle Counter Ch. 2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A22:0 | AI TxPDO-Map Cycle Counter Ch.2 | PDO Mapping TxPDO 35 | UINT8 | RO | 0x01 (1dec) |
1A22:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6010 (AI Inputs Ch. 2), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6010:14, 16 |
Index 1A24 AI TxPDO-Map Cycle Counter Ch. 3
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A24:0 | AI TxPDO-Map Cycle Counter Ch.3 | PDO Mapping TxPDO 37 | UINT8 | RO | 0x01 (1dec) |
1A24:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6020 (AI Inputs Ch. 3), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6020:14, 16 |
Index 1A26 AI TxPDO-Map Cycle Counter Ch. 4
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A26:0 | AI TxPDO-Map Cycle Counter Ch.4 | PDO Mapping TxPDO 39 | UINT8 | RO | 0x01 (1dec) |
1A26:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6030 (AI Inputs Ch. 4), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6030:14, 16 |
Index 1A28 AI TxPDO-Map Cycle Counter Ch. 5
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A28:0 | AI TxPDO-Map Cycle Counter Ch. 5 | PDO Mapping TxPDO 41 | UINT8 | RO | 0x01 (1dec) |
1A28:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6040 (AI Inputs Ch. 5), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6040:14, 16 |
Index 1A2A AI TxPDO-Map Cycle Counter Ch. 6
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A2A:0 | AI TxPDO-Map Cycle Counter Ch. 6 | PDO Mapping TxPDO 43 | UINT8 | RO | 0x01 (1dec) |
1A2A:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6050 (AI Inputs Ch. 6), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6050:14, 16 |
Index 1A2C AI TxPDO-Map Cycle Counter Ch. 7
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A2C:0 | AI TxPDO-Map Cycle Counter Ch. 6 | PDO Mapping TxPDO 45 | UINT8 | RO | 0x01 (1dec) |
1A2C:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6060 (AI Inputs Ch. 7), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6060:14, 16 |
Index 1A2E AI TxPDO-Map Cycle Counter Ch. 8
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A2E:0 | AI TxPDO-Map Cycle Counter Ch. 6 | PDO Mapping TxPDO 47 | UINT8 | RO | 0x01 (1dec) |
1A2E:01 | SubIndex 001 | PDO Mapping entry no. 1 (index 0x6060 (AI Inputs Ch. 8), entry 0x14 (Input Cycle Counter)) | UINT32 | RO | 0x6060:14, 16 |