0x1A00–0x1A03 | Mapping AI TxPDO Standard/Compact (INT16)

Index 1A00 AI TxPDO-Map Standard Ch. 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A00:0

AI TxPDO-Map Standard Ch.1

PDO Mapping TxPDO 1

UINT8

RO

0x0E (14dec)

1A00:01

SubIndex 001

PDO Mapping entry no. 1 (index 0x6000 (AI Inputs Ch. 1), entry 0x01 (Underrange))

UINT32

RO

0x6000:01, 1

1A00:02

SubIndex 002

PDO Mapping entry no. 2 (index 0x6000 (AI Inputs Ch. 1), entry 0x02 (Overrange))

UINT32

RO

0x6000:02, 1

1A00:03

SubIndex 003

PDO Mapping entry no. 3 (index 0x6000 (AI Inputs Ch. 1), entry 0x03 (Limit 1))

UINT32

RO

0x6000:03, 2

1A00:04

SubIndex 004

PDO Mapping entry no. 4 (index 0x6000 (AI Inputs Ch. 1), entry 0x05 (Limit 2))

UINT32

RO

0x6000:05, 2

1A00:05

SubIndex 005

PDO Mapping entry no. 5 (index 0x6000 (AI Inputs Ch. 1), entry 0x07 (Error))

UINT32

RO

0x6000:07, 1

1A00:06

SubIndex 006

PDO Mapping entry no. 6 (1 bits align)

UINT32

RO

0x0000:00, 1

1A00:07

SubIndex 007

PDO Mapping entry no. 7 (index 0x6000 (AI Inputs Ch. 1), entry 0x09 (Steady State))

UINT32

RO

0x6000:09, 1

1A00:08

SubIndex 008

PDO Mapping entry no. 8 (2 bits align)

UINT32

RO

0x0000:00, 2

1A00:09

SubIndex 009

PDO Mapping entry no. 9 (index 0x6000 (AI Inputs Ch. 1), entry 0x0C (Tare Active))

UINT32

RO

0x6000:0C, 1

1A00:0A

SubIndex 010

PDO Mapping entry no. 10 (index 0x6000 (AI Inputs Ch. 1), entry 0x0D (Warning))

UINT32

RO

0x6000:0D, 1

1A00:0B

SubIndex 011

PDO Mapping entry no. 11 (1 bits align)

UINT32

RO

0x0000:00, 1

1A00:0C

SubIndex 012

PDO Mapping entry no. 12 (index 0x6000 (AI Inputs Ch. 1), entry 0x0F (TxPDO State))

UINT32

RO

0x6000:0F, 1

1A00:0D

SubIndex 013

PDO Mapping entry no. 13 (index 0x6000 (AI Inputs Ch. 1), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6000:10, 1

1A00:0E

SubIndex 014

PDO Mapping entry no. 14 (index 0x6000 (AI Inputs Ch. 1), entry 0x11 (Value))

UINT32

RO

0x6000:11, 16

Index 1A01 AI TxPDO-Map Compact Ch. 1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A01:0

AI TxPDO-Map Compact Ch.1

PDO Mapping TxPDO 2

UINT8

RO

0x01 (1dec)

1A01:01

SubIndex 001

PDO Mapping entry no. 1 (index 0x6000 (AI Inputs Ch. 1), entry 0x11 (Value))

UINT32

RO

0x6000:11, 16

Index 1A02 AI TxPDO-Map Standard Ch. 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A02:0

AI TxPDO-Map Standard Ch.2

PDO Mapping TxPDO 3

UINT8

RO

0x0E (14dec)

1A02:01

SubIndex 001

PDO Mapping entry no. 1 (index 0x6010 (AI Inputs Ch. 2), entry 0x01 (Underrange))

UINT32

RO

0x6010:01, 1

1A02:02

SubIndex 002

PDO Mapping entry no. 2 (index 0x6010 (AI Inputs Ch. 2), entry 0x02 (Overrange))

UINT32

RO

0x6010:02, 1

1A02:03

SubIndex 003

PDO Mapping entry no. 3 (index 0x6010 (AI Inputs Ch. 2), entry 0x03 (Limit 1))

UINT32

RO

0x6010:03, 2

1A02:04

SubIndex 004

PDO Mapping entry no. 4 (index 0x6010 (AI Inputs Ch. 2), entry 0x05 (Limit 2))

UINT32

RO

0x6010:05, 2

1A02:05

SubIndex 005

PDO Mapping entry no. 5 (index 0x6010 (AI Inputs Ch. 2), entry 0x07 (Error))

UINT32

RO

0x6010:07, 1

1A02:06

SubIndex 006

PDO Mapping entry no. 6 (1 bits align)

UINT32

RO

0x0000:00, 1

1A02:07

SubIndex 007

PDO Mapping entry no. 7 (index 0x6010 (AI Inputs Ch. 2), entry 0x09 (Steady State))

UINT32

RO

0x6010:09, 1

1A02:08

SubIndex 008

PDO Mapping entry no. 8 (2 bits align)

UINT32

RO

0x0000:00, 2

1A02:09

SubIndex 009

PDO Mapping entry no. 9 (index 0x6010 (AI Inputs Ch. 2), entry 0x0C (Tare Active))

UINT32

RO

0x6010:0C, 1

1A02:0A

SubIndex 010

PDO Mapping entry no. 10 (index 0x6010 (AI Inputs Ch. 2), entry 0x0D (Warning))

UINT32

RO

0x6010:0D, 1

1A02:0B

SubIndex 011

PDO Mapping entry no. 11 (1 bits align)

UINT32

RO

0x0000:00, 1

1A02:0C

SubIndex 012

PDO Mapping entry no. 12 (index 0x6010 (AI Inputs Ch. 2), entry 0x0F (TxPDO State))

UINT32

RO

0x6010:0F, 1

1A02:0D

SubIndex 013

PDO Mapping entry no. 13 (index 0x6010 (AI Inputs Ch. 2), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6010:10, 1

1A02:0E

SubIndex 014

PDO Mapping entry no. 14 (index 0x6010 (AI Inputs Ch. 2), entry 0x11 (Value))

UINT32

RO

0x6010:11, 16

Index 1A03 AI TxPDO-Map Compact Ch. 2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A03:0

AI TxPDO-Map Compact Ch.2

PDO Mapping TxPDO 4

UINT8

RO

0x01 (1dec)

1A03:01

SubIndex 001

PDO Mapping entry no. 1 (index 0x6010 (AI Inputs Ch. 2), entry 0x11 (Value))

UINT32

RO

0x6010:11, 16