0x001E - UPS
![]() | The module is not supported by all devices. |
UPS (uninterruptible power supply)
This module provides UPS information.
0x8nn0 - Module Header
SubIndex | Type | Name | Value | Type | Access |
|---|---|---|---|---|---|
00 | VAR | Len |
| UNSIGNED16 | read-only |
01 | VAR | Address | 0x001E 00nn | UNSIGNED32 | read-only |
02 | VAR | Type | UPS | VISIBLE STRING | read-only |
03 | VAR | Name | UPS | VISIBLE STRING | read-only |
04 | VAR | Dev type | 0x001E 2710 | UNSIGNED32 | read-only |
0x8nn1 - UPS Information
SubIndex | Type | Name | Type | Access | ||
|---|---|---|---|---|---|---|
00 | VAR | Len | UNSIGNED16 | read-only | ||
01 | VAR | UPS Model | VISIBLE STRING | read-only | ||
02 | VAR | Vendor Name | VISIBLE STRING | read-only | ||
03 | VAR | Version | UNSIGNED8 | read-only | ||
04 | VAR | Revision | UNSIGNED8 | read-only | ||
05 | VAR | Build | UNSIGNED16 | read-only | ||
06 | VAR | Serial Number | VISIBLE STRING | read-only | ||
07 | VAR | Power-Status | UNSIGNED8 | read-only | ||
08 | VAR | Communication Status | UNSIGNED8 | read-only | ||
09 | VAR | Battery Status | UNSIGNED8 | read-only | ||
10 | VAR | Battery Capacity (in %) | UNSIGNED8 | read-only | ||
11 | VAR | Battery Runtime (in seconds) | UNSIGNED32 | read-only | ||
12 | VAR | Persistent Power Fail Count | BOOLEAN | read-only | ||
13 | VAR | Power Fail Counter | UNSIGNED32 | read-only | ||
14 | VAR | Fan Error | BOOLEAN | read-only | ||
15 | VAR | No Battery | BOOLEAN | read-only | ||
16 | VAR | Test Capacity | BOOLEAN | write-only | ||
17 | VAR | Battery Replace Date | VISIBLE STRING | read-only | ||
18 | VAR | Interval Service Status | BOOLEAN | read-only | ||
Compatibility List | S-UPS | 24V Beckhoff UPS/ 230V Beckhoff UPS | ||||
UPS Model | x | x | ||||
Vendor Name | x | x | ||||
Version | x | x | ||||
Revision | x | x | ||||
Build | x | x | ||||
Serial Number |
| x | ||||
Power-Status | x | x | ||||
Communication Status |
| x | ||||
Battery Status |
| x | ||||
Battery Capacity (in %) | x | x | ||||
Battery Runtime (in seconds) | x | x | ||||
Persistent Power Fail Counter | x | x | ||||
Power Fail Counter | x | x | ||||
Fan Error |
| x | ||||
No Battery |
| x | ||||
Test Capacity | x |
| ||||
Battery Replace Date |
| x | ||||
Interval Service Status |
| x | ||||
UPS Model Info | ||||||
1 = SUPS | ||||||
Power Status Info | ||||||
0 = UNKNOWN | ||||||
Communication Status Info | ||||||
0 = UNKOWN | ||||||
Battery Status Info | ||||||
0 = UNKNOWN | ||||||
Persistent Power Fail Counter Info |
|---|
TRUE = Power Fail Counter is stored persistently |
Test Capacity Info |
"TestCapacity" updates "Battery Runtime (in seconds)". Write a value to start the test. Disconnect the computer from the mains supply and wait until the computer switches off. Start the computer and read "Battery Runtime (in seconds)". |
Battery Replace Date Info |
Date of the last battery change. |
Interval Service Status Info |
Interval Service Status indicates whether the configured service interval has elapsed. |
0x8nn2 - UPS GPIO Pin Information
SubIndex | Type | Name | Type | Access | ||
|---|---|---|---|---|---|---|
00 | VAR | Len | UNSIGNED16 | read-only | ||
01 | VAR | Address | UNSIGNED16 | read-only | ||
02 | VAR | Offset | UNSIGNED8 | read-only | ||
03 | VAR | Params | UNSIGNED8 | read-only | ||
Compatibility List | S-UPS | 24V Beckhoff UPS/ 230V Beckhoff UPS | ||||
Address | x |
| ||||
Offset | x |
| ||||
Params | x |
| ||||
System requirements
MDP | Version 1.6 or higher |