0x0018 - Operating System

0x8nn0 – Module Header

SubIndex

Type

Name

Value

Type

Access

00

VAR

Len

 

UNSIGNED16

read-only

01

VAR

Address

0x0018 00nn

UNSIGNED32

read-only

02

VAR

Type

OperatingSystem

VISIBLE STRING

read-only

03

VAR

Name

<OS Name>

VISIBLE STRING

read-only

04

VAR

Dev type

0x0018 2710

UNSIGNED32

read-only

0x8nn1

SubIndex

Type

Name

Type

Access

00

VAR

Len

UNSIGNED16

read-only

01

VAR

OS Major Version

UNSIGNED32

read-only

02

VAR

OS Minor Version

UNSIGNED32

read-only

03

VAR

OS Build

UNSIGNED32

read-only

04

VAR

CSD Version

VISIBLE STRING

read-only

05

VAR

OS Version1)

VISIBLE STRING

read-only

1) available starting with MDP version 1.9.0.0.
The SubIndex 05 is an alternative to the format major.minor.build for TC/BSD and RT Linux®. In this case, the entire OS version is a concatenated string.

0x8nn2

SubIndex

Type

Name

Type

Access

01

VAR

Uptime in seconds

UNSIGNED64

read-only

System requirements

MDP

Version 1.3.42 or higher