DisplayPort (X200)

DisplayPort (X200) 1:

Recommended DisplayPort resolution for visualizations

A maximum resolution of 800 x 480 pixels is recommended for displaying visualizations.

The DisplayPort transmits image and sound signals and enables monitors or panels to be connected to the embedded PC.

DisplayPort (X200) 2:Fig.6: DisplayPort X300.

In this version, the embedded PC supports DisplayPort version 1.2.

The connection is backwards compatible with older DisplayPort versions and also supports the C9900-Z564 DisplayPort to DVI adapter solution with active video converter for monitors without a DisplayPort connection. Adapter solutions without an active video converter are not supported.

DisplayPort, pin assignment.

Pin

Connection

Pin

Connection

1

LVDS lane 0+

2

Ground

3

LVDS lane 0-

4

LVDS lane 1+

5

Ground

6

LVDS lane 1-

7

LVDS lane 2+

8

Ground

9

LVDS lane 2-

10

LVDS lane 3+

11

Ground

12

LVDS lane 3-

13

Config 1

14

Config 2

15

AUX channel+

16

Ground

17

AUX channel-

18

Hot-plug detection

19

Power supply: ground

20

Power supply: 3.3 V / 500 mA