DisplayPort (X200)
![]() | Recommended DisplayPort resolution for visualizations A maximum resolution of 800 x 480 pixels is recommended for displaying visualizations. |
The DisplayPort transmits image and sound signals and enables monitors or panels to be connected to the embedded PC.
In this version, the embedded PC supports DisplayPort version 1.2.
The connection is backwards compatible with older DisplayPort versions and also supports the C9900-Z564 DisplayPort to DVI adapter solution with active video converter for monitors without a DisplayPort connection. Adapter solutions without an active video converter are not supported.
Pin | Connection | Pin | Connection |
|---|---|---|---|
1 | LVDS lane 0+ | 2 | Ground |
3 | LVDS lane 0- | 4 | LVDS lane 1+ |
5 | Ground | 6 | LVDS lane 1- |
7 | LVDS lane 2+ | 8 | Ground |
9 | LVDS lane 2- | 10 | LVDS lane 3+ |
11 | Ground | 12 | LVDS lane 3- |
13 | Config 1 | 14 | Config 2 |
15 | AUX channel+ | 16 | Ground |
17 | AUX channel- | 18 | Hot-plug detection |
19 | Power supply: ground | 20 | Power supply: 3.3 V / 500 mA |