Update image
Notice | |
Loss of data All data on the MicroSD card will be deleted. Backup any data that you may have on the MicroSD card before proceeding. |
The new image will be copied directly to the MicroSD card in order to update the image of the Embedded PC.
The new image is made available by Beckhoff Service. Perform the update only after consulting with Beckhoff Service.
Requirements:
- Card reader for MicroSD cards.
Update the image as follows:
- 1. Switch the Embedded PC off and remove the MicroSD card from the Embedded PC.
- 2. Insert the MicroSD card into an external card reader and open the MicroSD card's folder tree.
- 3. Delete all files and folders on the MicroSD card.
- 4. Copy all files and folders of the new image to the empty MicroSD card.
- 5. Install the MicroSD card in the Embedded PC again.
- 6. Start the Embedded PC.
- The Embedded PC is started and saves the current hardware configuration in the folder Documents and Settings. The image has now been successfully updated.