Operating system

The Microsoft Windows Embedded Compact 7 operating system is used on the CX8191 Embedded PC. This operating system is optimized for the CX8191 Embedded PC. This means that not all features of Windows Embedded Compact 7 are available.

Security

For reasons of security the CERHOST and TELNET services are deactivated in the delivery state. To reactivate these services, you need a MicroSD card reader.

CERHOST

CERHOST is deactivated by current images on first start-up via the registry file CeRemoteDisplay_Disable.reg, which is located in the folder RegFiles.

To reactivate CERHOST you have to delete the file CeRemoteDisplay_Disable.reg from the folder RegFiles and also the folder Documents and Settings

Then reinsert the MicroSD card in the Embedded PC and reboot. The Embedded PC creates a new Document and Settings directory and then reboots automatically.

The Embedded PC is then accessible again via CERHOST.

TELNET

TELNET is deactivated by current images on first start-up via the registry file Telnet_Disable.reg, which is located in the folder RegFiles.

To reactivate TELNET you have to delete the file Telnet_Disable.reg from the folder RegFiles and also the folder Documents and Settings.

Then reinsert the MicroSD card in the Embedded PC and reboot. The Embedded PC creates a new Document and Settings directory and then reboots automatically.