Function F_CX81x0_LED_ERR
Since the CX8180 supports different protocols, the two LEDs WD and ERR on the CX8180 are not used by the firmware. This allows the user to create his own diagnosis messages. The LEDs can be used to indicate, for example, whether the CX8180 has received an IP address from the DHCP server or whether devices are exchanging data.
The function F_CX8180 CX8180 _LED_ERR controls the ERR LED on the CX8180. Various color and flashing modes can be used here. The possible LED colors are red and green.
VAR_INPUT
VAR_INPUT
eMode : E_CX81x0_LED;
END_VAR
eMode: way in which the LED lights up.
VAR_OUTPUT
F_CX8180_LED_ERR : INT;
F_CX8180_LED_ERR: -1, non-implemented flash code, 0 OK
Requirements
Development environment | Target platform | Hardware | PLC libraries to include |
---|---|---|---|