Care and maintenance

Notice

Use of incorrect spare parts

The use of spare parts not ordered from Beckhoff Service can lead to unsafe and faulty operation.

  • Only use spare parts that you have ordered from Beckhoff Service.

Beckhoff industrial PCs are manufactured from components of the highest quality and robustness. They are selected and tested for best interoperability, long-term availability and reliable function under the specified environmental conditions.

Nevertheless, some components of the industrial PC may be subject to a limited service life if they are operated under certain conditions, such as more demanding ambient conditions during operation or during storage, or if they are out of service for long periods of storage.

Beckhoff therefore recommends replacing some of the industrial PC components after the time after which predictions of the remaining service life of such components can no longer be reliably calculated.

Depending on the device used, the following components are involved:

The following table provides recommendations for the regular, precautionary replacement of the PC components:

Replacement recommendations for PC components

Component

Recommendation for replacement intervals (years)

UPS, battery pack

5 years

2.5-inch hard disk

5 years or after 20,000 operating hours at more than 40 °C or after 30,000 operating hours at less than 40 °C

Fan

5 years

CFast, SSD, MicroSD, CompactFlash®

10 years

Motherboard battery

5 years

Beckhoff is excluded from liability in the event of possible damage occurring during maintenance work. Before working on the device, you should have established ESD protection to prevent damage to the device through electrostatic discharge.

ESD protection

Notice

Electrostatic discharge

The replacement of device components without ESD protection can lead to functional impairment and destruction of the device.

  • If possible, apply ESD protection measures during maintenance work.

When working on electronic devices, there is a risk of damage due to ESD (electrostatic discharge), which can impair the function or destroy the device.

Protect the industrial PC and create an ESD-protected environment in which any electrostatic charges are discharged to the ground in a controlled manner and charging is prevented.

An ESD-protected environment can best be created by setting up ESD protection zones. The following measures serve this purpose:

If it is not possible to create an ESD protection zone, you can still protect the device against ESD damage. For example, the following measures can be used: