IP addresses
The CX8093 has two Ethernet interfaces that are visible to the operating system - X001 and X101/102.
![]() | IP addresses Make sure that the IP address of the PROFINET interface (X101/102) and the IP address of the programming interface (X001) belong to different networks (IP number ranges) (see PROFINET interface). |
X001
IP addressing takes place via the operating system; default is DHCP (represented in the operating system as FEC1)
X101/102 (PROFINET interface)
The IP addressing or PROFINET name resolution takes place via
the DIP switches (represented
in the operating system as TCCCATMP1).
The IP address cannot be registered in the operating system.
Hence all other services, apart from PROFINET, are no longer
possible via this interface (see PROFINET interface).
EtherCAT interface
The EtherCAT interface is a further Ethernet interface that is not visible in the operating system for the IP addressing.