Configure virtual local area network (VLAN)
From image version 140501, a virtual local area network (VLAN) can be configured on the Ethernet interface (X001). The VLAN forms a logical network segment and its own broadcast domain. This means that the network is subdivided regardless of the physical network topology on-site. The data traffic of a VLAN's associated devices is isolated from other VLANs.
The configuration takes place in the file /etc/boot.conf on the microSD card. Update the image first if you are using an older image version on the embedded PC (see: Update image).
Requirements:
- card reader for microSD cards
Proceed as follows:
- 1. Switch the embedded PC off and take the microSD card out of the embedded PC.
- 2. Insert the microSD card into an external card reader and open the microSD card's folder tree.
- 3. Open the
boot.conffile under\etcand navigate to the entries for the VLAN.
- 4. Edit the parameters
VLanEnabled, VLanID und VLanPriorityaccording to your requirements.
- Save the changes and reinstall the microSD card in the embedded PC. The settings will take effect after the device is started.