Ethernet RJ45 (X000, X001)
The two Ethernet interfaces are independent; no switch is integrated. The independent Ethernet interfaces can be configured in different ways. In the delivery state, the Ethernet interfaces (X000, X001) are configured for EtherCAT communication.
Note that an additional switch is required for a line topology.
Both Ethernet interfaces achieve speeds of 10/100/1000/2500 Mbit/s. The LEDs on the left-hand side of the interfaces indicate the connection status. The lower LED (LINK/ACT) indicates whether the interface is connected to a network. If this is the case, the LED lights up green. The LED flashes when data transmission is in progress on the interface.
The upper LED (SPEED) indicates the connection speed. At a speed of 10/100 Mbit/s, the LED does not light up. At a speed of 1000 Mbit/s, the LED lights up yellow. At 2500 Mbit/s the LED lights up green.
PIN | Signal | Description |
|---|---|---|
1 | T2 + | Pair 2 |
2 | T2 - | |
3 | T3 + | Pair 3 |
4 | T1 + | Pair 1 |
5 | T1 - | |
6 | T3 - | Pair 3 |
7 | T4 + | Pair 4 |
8 | T4 - |