DisplayPort (X200)

The DisplayPort transmits image and sound signals and enables monitors or panels to be connected to the embedded PC.

DisplayPort (X200) 1:Fig.6: DisplayPort X300.

In this version, the embedded PC supports DisplayPort version 1.4. This enables high resolutions of up to 8K at 60 Hz as well as the transmission of HDR (High Dynamic Range) content.

The connection is backwards compatible with older DisplayPort versions and also supports adapter solutions, such as DisplayPort to HDMI or DisplayPort to DVI (order identifier: C9900-Z468), for monitors without a DisplayPort connection.

DisplayPort, pin assignment.

Pin

Connection

Pin

Connection

1

LVDS lane 0+

2

Ground

3

LVDS lane 0-

4

LVDS lane 1+

5

Ground

6

LVDS lane 1-

7

LVDS lane 2+

8

Ground

9

LVDS lane 2-

10

LVDS lane 3+

11

Ground

12

LVDS lane 3-

13

Config 1

14

Config 2

15

AUX channel+

16

Ground

17

AUX channel-

18

Hot-plug detection

19

Power supply: ground

20

Power supply: 3.3 V / 500 mA

DisplayPort X300, resolution at the monitor.

Interface

Resolution in pixels

DisplayPort

max. 4096 x 2160 @60 Hz