DisplayPort (N011)
The DisplayPort transfers image and audio signal at the same time and is therefore suitable for connecting panels or monitors to the Embedded PC.
Version 1.1a of the DisplayPort (DisplayPort++) is installed on the Embedded PC. Adapters from DisplayPort to DVI-D or DisplayPort to HDMI can be used to connect monitors without DisplayPort to the Embedded PC.
Pin  | Connection  | Pin  | Connection  | 
|---|---|---|---|
1  | LVDS lane 0+  | 2  | Ground  | 
3  | LVDS lane 0-  | 4  | LVDS lane 1+  | 
5  | Ground  | 6  | LVDS lane 1-  | 
7  | LVDS lane 2+  | 8  | Ground  | 
9  | LVDS lane 2-  | 10  | LVDS lane 3+  | 
11  | Ground  | 12  | LVDS lane 3-  | 
13  | Config 1  | 14  | Config 2  | 
15  | AUX channel+  | 16  | Ground  | 
17  | AUX channel-  | 18  | Hot-plug detection  | 
19  | Power supply: Ground  | 20  | Power supply: 3.3 V / 500 mA  | 
Interface  | Resolution in pixels  | 
|---|---|
DisplayPort  | max. 2560x1600@60Hz  | 
DisplayPort with adapter, DisplayPort to DVI-D  | max. 1600x1200@60Hz  |