Types
The CX51x0 Embedded PC can be ordered with different software options. Use this overview in conjunction with the information on the name plate to ascertain the operating system and the TwinCAT version of the embedded PC.
The Embedded PCs CX5120, CX5130 and CX5140 are available with the following software options:
Ordering information | Description |
|---|---|
CX51x0-0100 | no operating system, no TwinCAT |
CX51x0-0110 | Windows Embedded Compact 7, no TwinCAT |
CX51x0-0111 | Windows Embedded Compact 7, TwinCAT 2 PLC runtime |
CX51x0-0112 | Windows Embedded Compact 7, TwinCAT 2 NC PTP runtime |
CX51x0-0113 | Windows Embedded Compact 7, TwinCAT 2 NC I runtime |
CX51x0-0115 | Windows Embedded Compact 7, TwinCAT 3 runtime (XAR) |
CX51x0-0120 | Windows Embedded Standard 7 P 32-bit, no TwinCAT |
CX51x0-0121 | Windows Embedded Standard 7 P 32-bit, TwinCAT 2 PLC runtime |
CX51x0-0122 | Windows Embedded Standard 7 P 32-bit, TwinCAT 2 NC PTP runtime |
CX51x0-0123 | Windows Embedded Standard 7 P 32-bit, TwinCAT 2 NC I runtime |
CX51x0-0125 | Windows Embedded Standard 7 P 32-bit, TwinCAT 3 runtime (XAR) |
CX51x0-0130 | Windows Embedded Standard 7 P 64-bit, no TwinCAT |
CX51x0-0135 | Windows Embedded Standard 7 P 64-bit, TwinCAT 3 runtime (XAR) |
CX51x0-0140 | Windows 10 IoT Enterprise 2016 LTSB 32-bit, no TwinCAT |
CX51x0-0141 | Windows 10 IoT Enterprise 2016 LTSB 32-bit, TwinCAT 2 PLC runtime |
CX51x0-0142 | Windows 10 IoT Enterprise 2016 LTSB 32-bit, TwinCAT 2 NC PTP runtime |
CX51x0-0143 | Windows 10 IoT Enterprise 2016 LTSB 32-bit, TwinCAT 2 NC I runtime |
CX51x0-0150 | Windows 10 IoT Enterprise 2016 LTSB 64-bit, no TwinCAT |
CX51x0-0155 | Windows 10 IoT Enterprise 2016 LTSB 64-bit, TwinCAT 3 runtime (XAR) |
CX51x0-0160 | Windows 10 IoT Enterprise 2019 LTSC 32-bit, no TwinCAT |
CX51x0-0161 | Windows 10 IoT Enterprise 2019 LTSC 32-bit, TwinCAT 2 PLC runtime |
CX51x0-0162 | Windows 10 IoT Enterprise 2019 LTSC 32-bit, TwinCAT 2 NC PTP runtime |
CX51x0-0163 | Windows 10 IoT Enterprise 2019 LTSC 32-bit, TwinCAT 2 NC I runtime |
CX51x0-0170 | Windows 10 IoT Enterprise 2019 LTSC 64-bit, no TwinCAT |
CX51x0-0175 | Windows 10 IoT Enterprise 2019 LTSC 64-bit, TwinCAT 3 runtime (XAR) |
CX51x0-0185 | TwinCAT/BSD, TwinCAT 3 runtime (XAR) |
CX51x0-0190 | Windows 10 IoT Enterprise 2021 LTSC 64-bit, no TwinCAT |
CX51x0-0195 | Windows 10 IoT Enterprise 2021 LTSC 64-bit, TwinCAT 3 runtime (XAR) |
A CX51x0 Embedded PC with Windows Embedded Compact 7 and TwinCAT/BSD requires a CFast card with a capacity of at least 20 GB. A CFast card with a capacity of at least 40 GB is required for Microsoft Windows Embedded Standard 7 P and Microsoft Windows 10 IoT Enterprise.
The support period for the Microsoft Windows Embedded Compact 7 operating system has already expired. Security updates can therefore no longer be provided. TwinCAT is only supported up to and including Build 4024.