Product overview

The CX2500-1061 Power over Ethernet module supports devices with PoE Class 0, 1, 2, 3 and 4 in accordance with the PoE standard IEEE 802.3af-2003. The maximum PoE power output is 15.4 W. The PoE supply voltage is generated internally, no external power supply is necessary. In the case of an overload of the CX2500-1061, the PoE supply shuts down for two seconds, then restarts. The diagnostic LEDs PWR, PoE, PM1 and PM2 provide information about the type of PoE supply (Mode A or B) as well as about the PoE class reported by the powered device.

The extension modules are connected on the left-hand side of the basic CPU module via a multi-pin connector. A maximum of four CX2500-xxxx modules can be plugged into the CX20xx series in any order, and one module can be plugged into the CX52x0, CX53x0 or CX56x0 series.

Scope of supply

The extension module is supplied by default with a protective cap for the left-hand multi-pin connector and two housing locking clips. The housing locking clips are used to securely connect the housing of the extension module to the embedded PC after installation.