CX1010-N010 connections

This module features a DVI-I and two USB interfaces.
DVI-I interface
The DVI-I interface transfers analog and digital data and is suitable for connection to analog graphics cards with 15 pin D-Sub connector and digital graphics cards with DVI-D output. The resolution at the screen or the Beckhoff Control Panel depends on the distance (maximum 5 m).
The DVI interface uses VGA signals, so that the connection of CRT VGA monitors to the CX1000 system using a DVI to VGA adapter is also possible.
This adapter is available as an accessory.
DVI-I socket:
Pin | Assignment | Pin | Assignment | Pin | Assignment |
|---|---|---|---|---|---|
1 | TMDS Data 2- | 9 | TMDS Data 1- | 17 | TMDS Data 0- |
2 | TMDS Data 2+ | 10 | TMDS Data 1+ | 18 | TMDS Data 0+ |
3 | TMDS Data 2/4 Shield | 11 | TMDS Data 1/3 Shield | 19 | TMDS Data 0/5 Shield |
4 | not connected | 12 | not connected | 20 | not connected |
5 | not connected | 13 | not connected | 21 | not connected |
6 | DDC Clock | 14 | + 5V Power | 22 | TMDS Clock Shield |
7 | DDC Data | 15 | Ground ( +5V, Analog H/V Sync) | 23 | TMDS Clock + |
8 | Analog Vertical Sync | 16 | Hot Plug Detect | 24 | TMDA Clock - |
Assignment cross
Pin | Assignment |
|---|---|
C1 | Analog Red Video Out |
C2 | Analog Green Video Out |
C3 | Analog Blue Video Out |
C4 | Analog Horizontal Sync |
Resolution at the monitor:
Note the supported resolution. You can only use the listed resolution.
Resolution in Pixel | Distance of the interface from the monitor |
|---|---|
1600 x 1200 | 5 m |
1280 x 1024 | 5 m |
1024 x 768 | 5 m |
800 x 600 | 5 m |
640 x 480 | 5 m |
USB interface:

The USB socket is a type A socket. The USB interface complies to USB 2.0 specification
Pin | Assignment | Typical Assignment |
|---|---|---|
1 | VBUS | Red |
2 | D- | White |
3 | D+ | Green |
4 | GND | Black |
Shell | Shield | Drain Wire |