Technical data
| CU8210-D001-0200 |
|---|---|
Dimensions (W x H x D) | 14.4 mm x 5.8 mm x 23.4 mm |
Weight | approx. 2.2 g |
| CU8210-D001-0200 |
|---|---|
Chipset | Realtek |
Number of transmitters | 1 transmitter, 1 receiver |
Standards | IEEE 802.11 b/g/n |
Data transfer rate | 1,2,5.5,6,11,12,18,22,24,30,36,48,54,60,90,120, and maximum 150 Mbit/s |
Encryption | WEP, WPA/WPA2 (TKIP/AES) |
Modulation method | BPSK/ QPSK/ 16-QAM/ 64-QAM |
Frequency band | 2.4 GHz ISM Band |
RF Output Power (Tolerance ±2 dBm) | 17 dBm - 802.11b 15 dBm - 802.11g 13 dBm - 802.11n |
Receiver sensitivity | -80 dBm - 802.11b -70 dBm - 802.11g -64 dBm - 802.11n |
| CU8210-D001-0200 |
|---|---|
Approvals | Europe, China |
| CU8210-D001-0200 |
|---|---|
Ambient temperature during operation | -20 °C ... +85 °C ambient temperature 5 to 90 % (non-condensing) |
Ambient temperature during storage | -40 °C ... +80 °C ambient temperature 5 to 90 % (non-condensing) |
Protection class | IP 20 |