Holding times
Discharge current [A] | Time to switch-off [s] | Usable energy [Wh] |
|---|---|---|
1.0 | 4060 | 27.07 |
2.0 | 2010 | 26.80 |
3.0 | 1300 | 26.00 |
4.0 | 900 | 24.00 |
5.0 | 670 | 22.33 |
6.0 | 460 | 18.40 |
7.0 | 320 | 14.93 |
8.0 | 250 | 11.67 |
9.0 | 100 | 6.00 |
Discharge current [A] | Time to switch-off [s] | Usable energy [Wh] |
|---|---|---|
1.0 | 4060 | 27.07 |
2.0 | 2010 | 26.80 |
3.0 | 1300 | 26.00 |
4.0 | 900 | 24.00 |
5.0 | 670 | 22.33 |
6.0 | 460 | 18.40 |
7.0 | 320 | 14.93 |
8.0 | 250 | 11.67 |
9.0 | 100 | 6.00 |