Intended use
The the Control Panel is intended for use as a control system for automation, visualization and communication in machine and system engineering.
The control panel is designed for industrial application in machine and system engineering. It serves as the operating unit of the machine or plant.
The DVI/USB extension technology integrated in the -0000 Control Panel enables the panel to be located up to 50 m away from the PC.
The CP-Link 4 technology integrated in the -0010 Control Panel enables the panel to be located up to 100 m away from the PC via a CP-Link 4 cable with optionally integrated or separate 24 V power supply, depending on the transmitter module.
The DVI/USB extension technology integrated in the CP3921-150x-0000 Control Panel enables the panel to be located up to 50 m away from the PC.
The CP-Link 4 technology integrated in the CP3921-150x-0010 Control Panel enables the panel to be located up to 100 m away from the PC via a CP-Link 4 cable. The 24 V power supply must be provided by a separate cable.
The device has been developed for an IP20 working environment. This involves finger protection and protection against solid foreign objects up to 12.5 mm. There is no protection against water. Operation of the devices in wet and dusty environments is not permitted.
The front of the device is designed for an IP50 working environment. There is complete protection against contact and dust in harmful quantities. It is not protected against water.
The rear of the device is designed for an IP20 working environment. It is protected against the penetration of fingers and solid foreign bodies of 12.5 mm in diameter or larger in size. It is not protected against water. Operation of the device in wet and dusty environments is not permitted. The specified limits for technical data must be adhered to.
The front of the panel PC is designed for an IP54 working environment. There is complete protection against contact and against dust in harmful quantities, as well as protection against splash water on all sides.
The rear side is designed for a working environment that meets the IP20 protection rating. This involves finger protection and protection against solid foreign objects up to 12.5 mm. There is no protection against water. Operation of the device in wet and dusty environments is not permitted. The specified limits for technical data must be adhered to.
The front of the panel PC is designed for an IP65 working environment. It offers full protection against contact and against dust, as well as protection against water jets (nozzle) from any angle.
The rear side is designed for a working environment that meets the IP20 protection rating. It is protected against the penetration of fingers and solid foreign bodies of 12.5 mm in diameter or larger in size. It is not protected against water. Operation of the device in wet and dusty environments is not permitted. The specified limits for technical data must be adhered to.
The device has been developed for an IP65 working environment. It offers full protection against contact (dust-tight) and against water jets (nozzle) from any angle.
The specified limits for technical data must be adhered to.
The device can be used within the documented operating conditions.
Potentially hazardous area
For the operation of the industrial PC in hazardous area Zone 2, the device adaptation by the is required.
The industrial PC is only suitable for the following hazardous areas:
- For Zone 2 where gas is present as a combustible material. Zone 2 means that the environment is usually either not explosive or only for a short period of time.
The industrial PC must be installed in a housing with an IP54 protection rating for gas according to EN 60079-7 or IEC 60079-7.
Improper use
Do not use the device outside the documented operating conditions.
The industrial PC is not suitable for use in the following environments:
- The industrial PC may only be used in Zone 2 and only with a suitable housing.
- The industrial PC is not suitable for use in aggressive environments, for example with aggressive gases or chemicals.
- The industrial PC is not suitable for residential areas. Relevant standards regarding interference emissions must be observed. The device must be installed in a housing or a control cabinet with suitable shielding.