Disassembly and disposal
Before you can remove the device from the control cabinet front, you must first disconnect the power supply and the cables (see chapter 6.1 Disconnecting the power supply and cables).
To remove the device from the control cabinet front, follow the steps shown in the following figure:
- 1. Loosen the clamping levers with a 2.5 mm Allen key (section A). Make sure that the device is secured against falling out of the control cabinet front.
- 2. Turn the clamping levers back by 90° onto the housing (section B).
- You can now remove the device from the control cabinet front.
- 3. To reattach the clamping levers to the housing, retighten them with the Allen key (section C).
- You have disassembled the device.
Disposal of the panel PC
When disposing of the device follow the national electronic scrap regulations. In order to dispose of the device, it must be removed and fully dismantled. Dispose of the components in the following way:
- Send plastic parts (polycarbonate, polyamide (PA6.6)) for plastics recycling.
- Take metal parts to the metal recycling collection point.
- Electronic parts such as fans and circuit boards must be disposed of in accordance with national electronic scrap regulations.
- Stick insulating tape over the poles of the CR2032 battery on the motherboard and dispose of the battery via the local battery recycling.